HCQ034E xxxxxxxx yyyy not found<br />

Explanation: The indicated item has been requested<br />

in the subcomm<strong>and</strong> <strong>and</strong> could not be located in the<br />

dump. Possibilities include:<br />

v Real device nnnn<br />

v Subchannel nnnn<br />

v Virtual device nnnn<br />

v Active radix tree elements<br />

v Device nnnn (could be real or virtual)<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> again using<br />

an element number that can be found in the dump.<br />

HCQ035E code not found in file fn ft<br />

Explanation: The indicated abend code could not be<br />

found in the indicated file.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: If this is a user-defined abend code,<br />

you may add it to the file indicated to display the<br />

meaning of the abend code <strong>and</strong> avoid this message. If<br />

this is a <strong>CP</strong>-generated abend code, report the problem<br />

to the <strong>IBM</strong> Support Center.<br />

HCQ036E Increment must be positive - incr<br />

Explanation: An increment must be positive, <strong>and</strong> a<br />

zero or negative value was found.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again using a positive increment value.<br />

HCQ037W Too many processors in dump<br />

Explanation: The number of processors found in the<br />

dump exceeds the number of processors that the <strong>VM</strong><br />

Dump Tool is set up to support (32).<br />

<strong>System</strong> Action: Processing continues. Only data from<br />

the supported number of processors are included in the<br />

trace information.<br />

User Response: Be aware that some trace data will<br />

be missing. If the dump was created by running in a<br />

virtual machine, run with fewer virtual processors next<br />

time. If this dump was taken on supported hardware,<br />

report the problem to the <strong>IBM</strong> Support Center.<br />

HCQ038E Output plus output length exceeds<br />

right margin xxxxxxxx offset set to zero<br />

Explanation: The output being produced by the<br />

subcomm<strong>and</strong> or macro has been indented too far to fit<br />

on a line. The first 8 characters of the text is displayed.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Use a smaller INDENT value <strong>and</strong><br />

enter the subcomm<strong>and</strong> or macro again.<br />

HCQ040E Not a valid decimal number - xxxxxxxx<br />

Explanation: The indicated value is required to be a<br />

decimal number, <strong>and</strong> was not.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again using a decimal number.<br />

HCQ041W control_block could not be found, some<br />

subcomm<strong>and</strong>s may fail<br />

Explanation: This is a warning when the partial dump<br />

is entered that SYSCM (SYStem CoMmon), the Frame<br />

Table, or some other <strong>CP</strong> control block could not be<br />

located.<br />

<strong>System</strong> Action: Processing continues.<br />

User Response: Be aware that some subcomm<strong>and</strong>s<br />

or macros may produce messages or errors because<br />

the given control block was not found.<br />

HCQ042E Error nnn setting variable<br />

HCQ034E HCQ043E<br />

Explanation: CMS returned an error when a REXX<br />

variable was being set.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Consult the explanation of the<br />

indicated error in the z/<strong>VM</strong>: <strong>System</strong> <strong>Messages</strong> <strong>and</strong><br />

<strong>Codes</strong> - CMS <strong>and</strong> REXX/<strong>VM</strong> book to determine if you<br />

have made an error. Enter the subcomm<strong>and</strong> or macro<br />

again with the correct parameters.<br />

HCQ043E Must be issued from a macro<br />

Explanation: This subcomm<strong>and</strong> can be issued only<br />

from within a macro.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> terminates.<br />

User Response: See if there is an alternate<br />

subcomm<strong>and</strong> or macro that can supply the required<br />

information. If none is found, then write a small macro<br />

to issue the required subcomm<strong>and</strong>.<br />