H<strong>CP</strong>9310E H<strong>CP</strong>9904I<br />

H<strong>CP</strong>9310E No soft abend dump files exist.<br />

Explanation: Soft abend processing tried to access a<br />

previously allocated soft abend dump file, <strong>and</strong> the file<br />

did not exist.<br />

<strong>System</strong> Action: The soft abend information collected<br />

is not written to a system data file. The system<br />

continues normal operation.<br />

User Response: Contact your system support<br />

personnel.<br />

H<strong>CP</strong>9311I The SNAP data parameter list is full.<br />

Some data will not be included in the<br />

dump for soft abend code.<br />

Explanation: This message informs the system<br />

operator there is no more room in the snap data<br />

parameter list to save the data specified by the failing<br />

module. The code is a <strong>CP</strong> soft abend code.<br />

<strong>System</strong> Action: Only those data items that were<br />

stored in the snap data parameter list will be in the soft<br />

abend dump.<br />

Operator Response: No action is required.<br />

H<strong>CP</strong>9423I Insufficient storage to allocate an<br />

SCMBK. Subchannel measurement will<br />

not be enabled for device XXXX<br />

Explanation: <strong>CP</strong> ran out of storage allocated for<br />

subchannel measurement blocks. Subchannel<br />

measurement is not enabled for the device.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

Operator Response: Increase the amount of storage<br />

that <strong>CP</strong> allocates for subchannel measurement blocks<br />

by adding/updating a STORAGE SCMBK statement in<br />

your system configuration file.<br />

H<strong>CP</strong>9500E Invalid substitutions in the following<br />

messages from module name<br />

Explanation: <strong>CP</strong> attempted to write a message to the<br />

console. The message is more than 8 characters long,<br />

which is the length limit for a system message. The<br />

module name variable refers to the module issuing the<br />

message.<br />

<strong>System</strong> Action: The erroneous message is typed<br />

without substitution, <strong>and</strong> system operation continues.<br />

User Response: Notify the system programmer.<br />

H<strong>CP</strong>9501E MSG*PAGING ERROR: CALLER:<br />

mmmmmm+nnnn DATA =<br />

substitution-data<br />

Explanation: A paging error has occurred that<br />

prevented the proper format presentation of an error<br />

message. The variables are as follows:<br />

468 z/<strong>VM</strong>: <strong>System</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong> — <strong>CP</strong><br />

mmmmmm<br />

The module issuing the message<br />

nnnn The offset within the module, where the error<br />

message was issued.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

Operator Response: If the failure persists, notify<br />

system support personnel.<br />

Programmer Response: If the problem persists,<br />

contact your <strong>IBM</strong> Support Center personnel to diagnose<br />

<strong>and</strong> correct the software problem.<br />

H<strong>CP</strong>9901I LKFAC configuration config_name<br />

Created<br />

Explanation: When SET LKFAC is specified with a<br />

configuration name, it connects a user to a Multi-Path<br />

Lock Facility (MPLF) RPQ simulation configuration. This<br />

message is issued if the configuration name was not<br />

previously defined in the configuration name table.<br />

<strong>System</strong> Action: The configuration name table is<br />

updated appropriately. Processing continues.<br />

User Response: None.<br />

H<strong>CP</strong>9902I userid Added to LKFAC configuration<br />

config_name<br />

Explanation: When SET LKFAC is specified with a<br />

configuration name it connects a user to a Multi-Path<br />

Lock Facility (MPLF) RPQ simulation configuration. This<br />

message is issued if the configuration name is already<br />

defined in the configuration name table.<br />

<strong>System</strong> Action: Processing continues.<br />

User Response: None.<br />

H<strong>CP</strong>9903I userid Removed from LKFAC<br />

configuration config_name<br />

Explanation: When SET LKFAC is issued without a<br />

configuration name it disconnects a user from a<br />

Multi-Path Lock Facility (MPLF) RPQ simulation<br />

configuration.<br />

<strong>System</strong> Action: The user is removed from the named<br />

MPLF simulation configuration.<br />

User Response: None.<br />

H<strong>CP</strong>9904I LKFAC configuration config_name<br />

Deleted<br />

Explanation: When SET LKFAC is issued without a<br />

configuration name it disconnects a user from a<br />

Multi-Path Lock Facility (MPLF) RPQ simulation<br />

configuration. This message is issued if the user is the<br />

last user connected to the configuration. In this case the<br />

configuration is deleted.<br />

<strong>System</strong> Action: The configuration name table is