HCQ097E HCQ106E<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again using a correct <strong>VM</strong>DBK address or user ID.<br />

HCQ097E Unexpected response received from<br />

<strong>CP</strong>U subcomm<strong>and</strong><br />

Explanation: Some subcomm<strong>and</strong>s <strong>and</strong> macros<br />

depend on the output of the <strong>CP</strong>U subcomm<strong>and</strong> to<br />

determine information about the <strong>CP</strong>Us represented in<br />

the dump. In this case, the response was not in the<br />

expected format.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the <strong>CP</strong>U subcomm<strong>and</strong> directly<br />

<strong>and</strong> see if produces normal output. If the problem<br />

persists, contact your <strong>IBM</strong> Support Center.<br />

HCQ098E Index xxx beyond table size of yyyyyy<br />

Explanation: This probably indicates an error in either<br />

the requested subcomm<strong>and</strong> or macro or in the <strong>CP</strong><br />

tables in the dump used for address translation. An<br />

index value from one level to the next being used to<br />

translate a <strong>CP</strong> address was found to be out of range.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Contact your <strong>IBM</strong> Support Center.<br />

HCQ099E Index index within table offset offset,<br />

below actual table start address -<br />

address<br />

Explanation: This probably indicates an error in either<br />

the requested subcomm<strong>and</strong> or macro or in the <strong>CP</strong><br />

tables in the dump used for address translation. An<br />

index value from one level to the next being used to<br />

translate a <strong>CP</strong> address was found to be out of range.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Contact your <strong>IBM</strong> Support Center.<br />

HCQ100I ASCE is a real space designation, no<br />

translation applies<br />

Explanation: The address provided as input is<br />

mapped 1–1 in real space. Thus, the translated address<br />

is the same as the input address.<br />

<strong>System</strong> Action: Processing continues.<br />

User Response: No action is required, this is an<br />

informational message.<br />

482 z/<strong>VM</strong>: <strong>System</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong> — <strong>CP</strong><br />

HCQ101E Region region index non-zero<br />

Explanation: The ASCE for the address provided is<br />

an STD, RSTD, or RTTD. The index for the indicated<br />

Region table is non-zero, which is inconsistent. The<br />

provided input address is not translatable via this ASCE.<br />

<strong>System</strong> Action: Processing terminates.<br />

User Response: Issue the subcomm<strong>and</strong> again with a<br />

different address.<br />

HCQ102E ASCE format is not recognized<br />

Explanation: The ASCE used in the translation of the<br />

address provided is not an STD, RSTD, or RTTD. The<br />

provided input address is not translatable via this ASCE.<br />

<strong>System</strong> Action: Processing terminates.<br />

User Response: Issue the subcomm<strong>and</strong> again with a<br />

different address.<br />

HCQ103E TT bits level mismatch in valid table at<br />

address: data<br />

Explanation: The TT bits in the indicated table are<br />

inconsistent with the rest of the table structure. The<br />

provided input address is not translatable via this ASCE.<br />

<strong>System</strong> Action: Processing terminates.<br />

User Response: Issue the subcomm<strong>and</strong> again with a<br />

different address.<br />

HCQ104I Name H<strong>CP</strong><strong>CP</strong>E not found<br />

Explanation: In trying to create a map of the modules<br />

in storage, the last resident module of <strong>CP</strong>, H<strong>CP</strong><strong>CP</strong>E,<br />

could not be found in the dump.<br />

<strong>System</strong> Action: Processing continues.<br />

User Response: No action is required. If the problem<br />

persists, contact the <strong>IBM</strong> Support Center.<br />

HCQ105E Error getting controlblock<br />

Explanation: An error was encountered when trying to<br />

access the indicated control block. This error may have<br />

resulted from either reading the actual dump file, or that<br />

the required page was not included in the dump.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: If the problem persists, contact the<br />

<strong>IBM</strong> Support Center.<br />

HCQ106E ADDRSCAN is set OFF - comm<strong>and</strong><br />

Explanation: The indicated comm<strong>and</strong> was received by<br />

Address SCAN from a macro, but the Address Scan<br />

environment is not active.