H<strong>CP</strong>2828E S<strong>CP</strong>DATA length exceeds maximum<br />

allowed (nnnn)<br />

Explanation: The specified data is too long or, in the<br />

case of appending or overlaying existing data, the<br />

resulting string is too long. nnnn is the maximum<br />

allowable length.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not executed; no<br />

LOADDEV data is modified.<br />

User Response: None<br />

H<strong>CP</strong>2829E S<strong>CP</strong>DATA does not contain a valid hex<br />

string<br />

Explanation: An odd number of characters was<br />

entered or the data contains characters other than 0-F.<br />

An even number of characters is required because each<br />

byte of data is represented by two hex characters.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not executed; no<br />

LOADDEV data is modified. If the error is from a<br />

directory statement, then the statement is skipped.<br />

User Response: Correct the error <strong>and</strong> issue the<br />

comm<strong>and</strong>.<br />

H<strong>CP</strong>2830I The variations of this message are<br />

explained below.<br />

MESSAGES: VSWITCH SYSTEM switchnm status is<br />

v defined<br />

v controller not available<br />

v disconnected following error. userid was last<br />

VSWITCH controller<br />

v disconnected requiring operator intervention. userid<br />

was last VSWITCH controller<br />

v devices attached. userid is VSWITCH controller<br />

v initialization in progress. userid is VSWITCH<br />

controller<br />

v device not ready. userid is VSWITCH controller<br />

v ready. userid is VSWITCH controller<br />

v device detach in progress. userid is VSWITCH<br />

controller<br />

v detach VSWITCH pending. userid is VSWITCH<br />

controller<br />

v in error recovery. userid is new VSWITCH controller<br />

v restarting. userid is VSWITCH controller<br />

Explanation: A virtual switch is defined with a real<br />

device address to connect it to a QDIO OSA Express<br />

device. This message is used to report changes in the<br />

status of the connection to that device.<br />

v defined<br />

The virtual switch is created, but no real device<br />

address has been specified.<br />

v controller not available<br />

A T<strong>CP</strong>/IP virtual switch controller is not available to<br />

manage the device. The connection to the real<br />

hardware LAN is not operational.<br />

v disconnected following error. userid was last<br />

VSWITCH controller<br />

The virtual switch is created, but the connection to<br />

the real hardware LAN is not operational.<br />

v disconnected requiring operator intervention.<br />

userid was last VSWITCH controller<br />

The virtual switch is created, but the connection to<br />

the real hardware LAN is not working. The operator<br />

must take action to make it operational.<br />

v devices attached. userid is VSWITCH controller<br />

The OSA Express devices are attached to a virtual<br />

switch controller, but the connection to the real<br />

hardware LAN is not operational.<br />

v initialization in progress. userid is VSWITCH<br />

controller<br />

Initialization of the OSA Express devices has begun.<br />

The connection to the real hardware LAN is not<br />

operational.<br />

v device not ready. userid is VSWITCH controller<br />

Initialization has completed, but the virtual switch<br />

controller received a response from the device<br />

indicating that the device is not ready. The<br />

connection to the real hardware LAN is not<br />

operational.<br />

v ready. userid is VSWITCH controller<br />

The connection to the real hardware LAN is<br />

operational.<br />

v device detach in progress. userid is VSWITCH<br />

controller<br />

The connection to the real hardware LAN is not<br />

operational.<br />

v detach VSWITCH pending. userid is VSWITCH<br />

controller<br />

The virtual switch is being removed from the system.<br />

v in error recovery. userid is new VSWITCH<br />

controller<br />

An error occurred <strong>and</strong> the system is attempting to<br />

recover by switching to a backup OSA Express<br />

device <strong>and</strong> virtual switch controller.<br />

v restarting. userid is VSWITCH controller<br />

An error occurred but there is no backup device<br />

operational for the virtual switch. The system is<br />

attempting to restart the failing device.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

<strong>System</strong> Programmer Response: The OSA Express<br />

device is controlled by a z/<strong>VM</strong> T<strong>CP</strong>/IP virtual machine<br />

acting as the virtual switch controller. In some cases,<br />

the suggested action is to issue z/<strong>VM</strong> T<strong>CP</strong>/IP<br />

comm<strong>and</strong>s or investigate messages on the z/<strong>VM</strong><br />

T<strong>CP</strong>/IP console.<br />

v defined<br />

H<strong>CP</strong>2828E H<strong>CP</strong>2830I<br />

Chapter 3. <strong>System</strong> <strong>Messages</strong> 315