HCQ051E Reason code code on TOD conversion<br />

Explanation: The indicated reason code was received<br />

from the DATETIMESUBTRACT CSL routine.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Examine the meaning of the reason<br />

code in z/<strong>VM</strong>: CMS Callable Services Reference; then<br />

enter the subcomm<strong>and</strong> again.<br />

HCQ052E Unknown <strong>CP</strong>U number - cpuno<br />

Explanation: The <strong>CP</strong>U number indicated is not<br />

represented in the dump.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again with a correct <strong>CP</strong>U number.<br />

HCQ053E xxxxxxxx is not * or a decimal number<br />

Explanation: The indicated value is not an asterisk or<br />

a valid decimal number.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> again with an<br />

asterisk or decimal number.<br />

HCQ054W Offset incorrect, set to nnnnn<br />

Explanation: The absolute offset value is larger than<br />

the display area of the screen or zero, or an increased<br />

or decreased indentation value has caused output to<br />

shift off the left or right side of the viewing area.<br />

<strong>System</strong> Action: Processing continues with the indent<br />

offset value set to 0.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again with a correct offset value.<br />

HCQ055E length too large, yyy max<br />

Explanation: The value indicated is greater than the<br />

allowed maximum of yyy.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again with a value in the right range.<br />

HCQ056E Must be run in a <strong>VM</strong>DUMPTL<br />

environment<br />

Explanation: An XEDIT macro was invoked that<br />

requires the <strong>VM</strong> Dump Tool to run, but the <strong>VM</strong> Dump<br />

Tool is not a active.<br />

<strong>System</strong> Action: The macro terminates.<br />

User Response: Bring up the <strong>VM</strong> Dump Tool<br />

(<strong>VM</strong>DUMPTL EXEC) <strong>and</strong> enter the macro again.<br />

HCQ057E Address cannot be resolved - addr<br />

Explanation: An error was encountered when trying to<br />

resolve the indicated symbol or address. If a symbol<br />

was found, it is shorter than 6 characters or longer than<br />

8. If an open parenthesis was found, the next character<br />

was not G or R or the register number was not between<br />

0 <strong>and</strong> F or 0 <strong>and</strong> 15. If a plus sign or dash was found,<br />

no value was found after that character.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Correct the indicated value <strong>and</strong> enter<br />

the subcomm<strong>and</strong> or macro again.<br />

HCQ058E Error nn on STATE for file fn ft<br />

Explanation: The indicated error was received from a<br />

STATE on the BLOCK library file listed.<br />

<strong>System</strong> Action: The file is not used to find BLOCK<br />

definition information.<br />

User Response: See the STATE comm<strong>and</strong> in the<br />

z/<strong>VM</strong>: CMS Comm<strong>and</strong>s <strong>and</strong> Utilities Reference for a<br />

description of the comm<strong>and</strong> <strong>and</strong> its responses.<br />

HCQ059E Unknown {real<br />

device|subchannel|virtual device}<br />

Explanation: The real or virtual device or subchannel<br />

cannot be located in the dump.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Locate <strong>and</strong> correct the item indicated<br />

<strong>and</strong> enter the subcomm<strong>and</strong> or macro again.<br />

HCQ060E macroname supports only <strong>CP</strong> dumps<br />

Explanation: Many subcomm<strong>and</strong>s <strong>and</strong> macros<br />

reference <strong>CP</strong> data structures to locate information. The<br />

dump currently being processed is not recognized as a<br />

<strong>CP</strong> dump.<br />

<strong>System</strong> Action: The macro terminates.<br />

HCQ051E HCQ061E<br />

User Response: If this is not a <strong>CP</strong> dump, then this<br />

subcomm<strong>and</strong> or macro cannot be used.<br />

HCQ061E Unknown -<br />

value<br />

Explanation: The input value was not found to be<br />

either a user ID or a <strong>VM</strong>DBK address.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Locate the correct user ID or<br />

Chapter 3. <strong>System</strong> <strong>Messages</strong> 477