H<strong>CP</strong>9267E H<strong>CP</strong>9301E<br />

H<strong>CP</strong>9267E The system is unable to determine the<br />

dump device settings following a<br />

non-destructive dump. The dump<br />

device is now set to the printer. To<br />

assign a different device, enter the SET<br />

DUMP comm<strong>and</strong>.<br />

Explanation: After taking a non-destructive dump,<br />

either through entering the SNAPDUMP comm<strong>and</strong> or<br />

because of a system error, the system was unable to<br />

determine the settings specified in the last SET DUMP<br />

comm<strong>and</strong>.<br />

<strong>System</strong> Action: The dump is routed to the printer.<br />

Operator Response: Enter the SET DUMP comm<strong>and</strong><br />

to assign a different dump device if the printer is not the<br />

preferred device.<br />

H<strong>CP</strong>9269E Tape rdev dump unit not available<br />

following non-destructive dump. The<br />

system is attempting to obtain DASD<br />

dump space.<br />

Explanation: After taking a non-destructive dumpe,<br />

the tape dump device will not be available for another<br />

dump until it is made ready by the system operator. In<br />

addition, the dump device will need to be attached to<br />

the ID of the dump owner in order to process the dump.<br />

<strong>System</strong> Action: None.<br />

Operator Response: If a dump device of DASD or<br />

printer is not acceptable, enter the SET DUMP<br />

comm<strong>and</strong> to define a desired dump device.<br />

H<strong>CP</strong>9275I SYSTEM TERMINATION IN PROGRESS;<br />

RESTART IGNORED<br />

Explanation: A system restart interrupt was presented<br />

during the termination process.<br />

<strong>System</strong> Action: The interrupt is ignored <strong>and</strong><br />

termination continues.<br />

Operator Response: None. If you wish to stop the<br />

termination process, you must IPL.<br />

H<strong>CP</strong>9276W SYSTEM TERMINATION FAILURE;<br />

PROGRAM ERROR<br />

Explanation: A program check or an SVC interrupt<br />

occurred during the termination process.<br />

<strong>System</strong> Action: The system enters a wait state<br />

(wait-state code = 9276).<br />

Operator Response: Take a st<strong>and</strong>-alone dump <strong>and</strong><br />

contact <strong>IBM</strong> for software support.<br />

466 z/<strong>VM</strong>: <strong>System</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong> — <strong>CP</strong><br />

H<strong>CP</strong>9277I SYSTEM TERMINATION COMPLETE,<br />

ATTEMPTING RESTART<br />

Explanation: The system termination process has<br />

completed without further incident.<br />

<strong>System</strong> Action: The system attempts to reload itself.<br />

Operator Response: See the preceding messages for<br />

the cause of the system termination <strong>and</strong> use the<br />

applicable operator response.<br />

H<strong>CP</strong>9300E A system {soft|snapdump} abend code<br />

has occurred on <strong>CP</strong>U nnnn [for user<br />

userid,] ({where|<strong>and</strong>} the virtual <strong>CP</strong>U<br />

has been put into stopped state)<br />

Explanation: The system is generating either a soft or<br />

snapdump abend. The nnnn variable indicates the<br />

processor that the problem occurred on. The code<br />

variable is a <strong>CP</strong> soft or snapdump abend code. The<br />

userid variable is sent to the system operator to indicate<br />

the user ID who received the abend. When the soft or<br />

snapdump abend puts the <strong>CP</strong>U into a stopped state,<br />

the message will also include that information. If the<br />

virtual <strong>CP</strong>U is put into a stopped state, the virtual<br />

machine must be restarted.<br />

<strong>System</strong> Action: The system spools the<br />

general-purpose registers, control registers,<br />

floating-point registers, clocks, prefix pages, trace table,<br />

<strong>and</strong> host pages addressed by the general-purpose<br />

registers to a reader spool file. The system then<br />

continues normal operation.<br />

Operator Response: Contact your system support<br />

personnel.<br />

Programmer Response: Examine the dump or the<br />

<strong>CP</strong> abend code, or both, to determine the error<br />

condition. If the problem persists, contact your <strong>IBM</strong><br />

Support Center personnel to diagnose <strong>and</strong> correct the<br />

software error.<br />

H<strong>CP</strong>9301E Snap data processing completed<br />

unsuccessfully for soft abend code<br />

Explanation: This message informs the system<br />

operator that some of the data requested to be<br />

preserved <strong>and</strong> dumped by the failing module could not<br />

be saved. The code variable is a <strong>CP</strong> soft abend code.<br />

<strong>Messages</strong> H<strong>CP</strong>9302I, H<strong>CP</strong>9303I, H<strong>CP</strong>9304I,<br />

H<strong>CP</strong>9305I, or H<strong>CP</strong>9306I are subsequently issued to<br />

detail why the data could not be saved.<br />

<strong>System</strong> Action: The system continues to take the<br />

dump.<br />

Operator Response: See the response of the<br />

accompanying message.