Then reenter the comm<strong>and</strong>.<br />

H<strong>CP</strong>2880E userid vaddr is not linked, CSE LINK I/O<br />

error, code cc.<br />

Explanation: The minidisk vaddr, owned by user<br />

userid, cannot be linked as requested because CSE<br />

received an I/O error when trying to read or write the<br />

CSE track. The error code, cc, describes one of the<br />

following I/O errors:<br />

Code Meaning<br />

01 A write error occurred.<br />

02 The CSE track does not contain the expected<br />

CSE format, or the drive presented a real<br />

hardware I/O error.<br />

03 The CSE map record length on the CSE track<br />

is smaller than the start cylinder for this<br />

minidisk. This indicates that an incorrect CYL<br />

oper<strong>and</strong> was specified on a CSELVOL or<br />

CSELDEV macro.<br />

04 An I/O error occurred because of invalid<br />

channel comm<strong>and</strong> words.<br />

05 A hardware error occurred.<br />

<strong>System</strong> Action: The requested link is denied.<br />

User Response: Make sure that the device where the<br />

minidisk is located is not presenting real hardware I/O<br />

errors <strong>and</strong> that the volume is correctly formatted for<br />

CSE.<br />

H<strong>CP</strong>2881E XLINK RESET is not allowed. There is<br />

no CSE LINK control on this system.<br />

Explanation: An XLINK RESET sysname comm<strong>and</strong><br />

was entered on a system identified in H<strong>CP</strong>SYS as<br />

being excluded from the CSE complex.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not processed.<br />

User Response: Make sure that you are using the<br />

XLINK RESET comm<strong>and</strong> on a CSE-controlled system.<br />

H<strong>CP</strong>2882E XLINK RESET is not allowed. There is<br />

no CSE LINK control on system<br />

sysname.<br />

Explanation: An XLINK RESET sysname comm<strong>and</strong><br />

was entered, but the specified system is not identified in<br />

H<strong>CP</strong>SYS as being a member of the CSE complex.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not processed.<br />

User Response: Make sure that you are specifying<br />

the correct system name <strong>and</strong> that the correct CSE<br />

system table is active on your system.<br />

H<strong>CP</strong>2883I Volume volidn is not controlled by CSE<br />

LINK.<br />

Explanation: An XLINK CHECK comm<strong>and</strong> was<br />

entered. The volume volidn is not under control of CSE<br />

according to the CSELVOL INCLUDE <strong>and</strong> CSELVOL<br />

EXCLUDE lists that are currently active on this system.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is processed, <strong>and</strong><br />

system operation continues.<br />

User Response: If this volume should be under<br />

XLINK control, it must be added to the CSELVOL macro<br />

oper<strong>and</strong>s in H<strong>CP</strong>SYS.<br />

H<strong>CP</strong>2884I Volume volidn is controlled by CSE<br />

LINK.<br />

Explanation: An XLINK CHECK comm<strong>and</strong> was<br />

entered. The volume volidn is under control of CSE<br />

according to the CSELVOL INCLUDE <strong>and</strong> CSELVOL<br />

EXCLUDE lists that are currently active on this system.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is processed, <strong>and</strong><br />

system operation continues.<br />

User Response: If this volume should not be under<br />

XLINK control, it must be deleted from the CSELVOL<br />

macro oper<strong>and</strong>s in H<strong>CP</strong>SYS.<br />

H<strong>CP</strong>2885E Volume volidn is offline.<br />

Explanation: The volume volidn is offline <strong>and</strong> cannot<br />

be acted upon by CSE.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not processed.<br />

User Response: Vary the volume online <strong>and</strong> reenter<br />

the comm<strong>and</strong>.<br />

H<strong>CP</strong>2886D Are you ready for XLINK RESET of<br />

system sysname, volume volidn? Enter<br />

YES or NO:<br />

Explanation: You have entered an XLINK RESET<br />

comm<strong>and</strong> to reset the link flags for system sysname on<br />

volume volidn.<br />

<strong>System</strong> Action: None until you reply YES or NO.<br />

User Response: Before replying YES:<br />

H<strong>CP</strong>2880E H<strong>CP</strong>2886D<br />

v Make sure you typed the comm<strong>and</strong> correctly.<br />

v Make sure the system sysname is really down or has<br />

no access to volume volidn anymore.<br />

v Enter a SYSTEM RESET comm<strong>and</strong> <strong>and</strong> a SYSTEM<br />

CLEAR comm<strong>and</strong> on the down system to make sure<br />

that it will not complete any outst<strong>and</strong>ing I/Os or issue<br />

any new I/Os to the volume(s) being RESET.<br />

v If this is a RESET for one volume while another<br />

system is still running, make sure that the volume is<br />

detached from that system on the system being<br />

RESET.<br />

Chapter 3. <strong>System</strong> <strong>Messages</strong> 325