H<strong>CP</strong>791E H<strong>CP</strong>796E<br />

error above the message. The directory program<br />

terminates, without bringing a new directory on line,<br />

after scanning the remaining statements for syntax.<br />

User Response: Correct the <strong>CP</strong>U statement <strong>and</strong><br />

reissue the DIRECTXA comm<strong>and</strong>.<br />

H<strong>CP</strong>791E DUPLICATE <strong>CP</strong>U DEFINITION<br />

FOLLOWING {PROFILE profname or<br />

USER userid}<br />

Explanation: A directory <strong>CP</strong>U statement for this profile<br />

profname or user userid contains a cpuaddr parameter<br />

that is a duplicate of one already specified for this user.<br />

<strong>System</strong> Action: The statement in error is displayed,<br />

followed by the message. The program is terminated<br />

after scanning the remaining statements for syntax,<br />

without bringing a new directory on line.<br />

Operator Response: Correct the <strong>CP</strong>U statement <strong>and</strong><br />

reissue the DIRECTXA comm<strong>and</strong>.<br />

H<strong>CP</strong>792E A BASE <strong>CP</strong>U HAS ALREADY BEEN<br />

DEFINED FOLLOWING {PROFILE<br />

profname or USER userid}<br />

Explanation: A directory <strong>CP</strong>U statement for this profile<br />

profname or user userid contains the BASE parameter<br />

after <strong>CP</strong> found BASE on a previous <strong>CP</strong>U statement for<br />

this user.<br />

<strong>System</strong> Action: The statement in error is displayed<br />

followed by the message. The program is terminated,<br />

after scanning the remaining statements for syntax,<br />

without bringing the new directory on line.<br />

Operator Response: Correct the <strong>CP</strong>U statement <strong>and</strong><br />

reissue the DIRECTXA comm<strong>and</strong>.<br />

H<strong>CP</strong>793E LOGICAL RECORD LENGTH OR<br />

RECORD FORMAT IS INCORRECT<br />

Explanation: The requested CMS file that contains the<br />

directory source is not in fixed-record (F) format, or the<br />

logical record length is not 80.<br />

<strong>System</strong> Action: Directory processing terminates.<br />

User Response: Correct the requested CMS file <strong>and</strong><br />

reissue the comm<strong>and</strong>.<br />

H<strong>CP</strong>794E dasd rdev - ACCESS IS PROHIBITED<br />

ON {SUSBYSTEM| VOLUME volid} DUE<br />

TO STATUS ERROR - RC = -<br />

ssid.p-cc-dd<br />

Explanation: This message is generated when the<br />

storage director cannot determine the status of the<br />

volume, or cannot synchronize the volume with the data<br />

in nonvolatile storage.<br />

The variables in the message are as follows:<br />

rdev The device used to report the condition<br />

208 z/<strong>VM</strong>: <strong>System</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong> — <strong>CP</strong><br />

volid The volume identifier of the affected device<br />

rc The reason code<br />

ssid.p-cc-dd<br />

The subsystem identifier, storage path number,<br />

controller identifier, <strong>and</strong> device unit address of<br />

the affected hardware components<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

Operator Response: Contact your system support<br />

personnel.<br />

Programmer Response: Examine the EREP records<br />

(OBR) for additional details of the failure. Refer to the<br />

hardware <strong>System</strong> Reference Library (SRL) manuals for<br />

sense data formats <strong>and</strong> descriptions. Contact the<br />

appropriate hardware service personnel.<br />

H<strong>CP</strong>795E STATEMENT CONFLICTS WITH<br />

{CLASS VALUE|STORAGE SIZE} ON<br />

USER STATEMENT FOLLOWING USER<br />

userid<br />

Explanation: A CLASS, STORAGE or MAXSTORAGE<br />

control statement is present in the directory entry for the<br />

indicated user, but the USER directory control statement<br />

has a value other than blank or an asterisk ( * ) in the<br />

corresponding field.<br />

<strong>System</strong> Action: The CLASS, STORAGE or<br />

MAXSTORAGE card image is displayed above the<br />

message. The directory program terminates without<br />

bringing a new directory on line after scanning the<br />

remaining statements for syntax.<br />

User Response: Remove the CLASS, STORAGE or<br />

MAXSTORAGE control statement, or change the user<br />

control statement to eliminate the conflict. Enter the<br />

DIRECTXA comm<strong>and</strong> again.<br />

H<strong>CP</strong>796E MAXIMUM NUMBER OF CRYPTOS<br />

ALREADY DEFINED ON <strong>CP</strong>U<br />

STATEMENTS FOLLOWING {PROFILE<br />

profname|USER userid}<br />

Explanation: More than two directory <strong>CP</strong>U statements<br />

for this profile profname or user userid specify the<br />

CRYPTO parameter. A maximum of two virtual crypto<br />

facilities may be defined for a virtual machine.<br />

<strong>System</strong> Action: The statement in error is displayed,<br />

followed by the message. The directory program is<br />

terminated after scanning the remaining statements for<br />

syntax, without bringing the new directory on line.<br />

Operator Response: Correct the <strong>CP</strong>U statements so<br />

that CRYPTO is specified on no more than two <strong>and</strong><br />

enter the DIRECTXA comm<strong>and</strong> again.