eal storage area of an operating system running under<br />

z/<strong>VM</strong>.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not executed;<br />

system operation continues.<br />

User Response: Reenter the comm<strong>and</strong>, using only<br />

valid hexadecimal locations within the range of the<br />

address space.<br />

H<strong>CP</strong>161I END or ALL was specified or defaulted<br />

<strong>and</strong> storage exceeds over maximum<br />

dumpable address hexloc. Pages over<br />

that address will not be dumped<br />

Explanation: <strong>VM</strong>DUMP was requested to dump to the<br />

end of configured storage, but the highest address that<br />

<strong>VM</strong>DUMP can dump is X'7FFFEFFF'.<br />

<strong>System</strong> Action: <strong>VM</strong>DUMP dumps storage up to that<br />

limit. Processing continues.<br />

User Response: None.<br />

H<strong>CP</strong>162E Hexloc hexloc exceeds maximum<br />

dumpable address hexloc <strong>and</strong> cannot<br />

be dumped<br />

Explanation: All or part of the specified range<br />

exceeds the maximum address that <strong>VM</strong>DUMP can<br />

process.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not executed.<br />

<strong>System</strong> operation continues.<br />

User Response: Enter the comm<strong>and</strong> again using only<br />

hexadecimal locations below the maximum address that<br />

<strong>VM</strong>DUMP can process.<br />

H<strong>CP</strong>163E STORE exceeds maximum register<br />

Explanation: The STORE comm<strong>and</strong> has specified that<br />

a number of oper<strong>and</strong>s are to be stored in contiguous<br />

registers, <strong>and</strong> the number of oper<strong>and</strong>s specified would<br />

place the store beyond the valid register range.<br />

<strong>System</strong> Action: The system has stored up to, <strong>and</strong><br />

including, the highest register allowed for the store<br />

function.<br />

User Response: Verify that the store comm<strong>and</strong> was<br />

entered correctly <strong>and</strong> that the beginning register was<br />

correctly specified. If they were not, reissue the STORE<br />

comm<strong>and</strong>, specifying the correct registers <strong>and</strong><br />

oper<strong>and</strong>s.<br />

H<strong>CP</strong>164E Hexloc hexloc non-addressable storage<br />

Explanation: The hexadecimal address specified with<br />

the comm<strong>and</strong> is within a nonaddressable storage range.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not executed;<br />

system operation continues.<br />

User Response: Reissue the comm<strong>and</strong> specifying a<br />

valid hexadecimal address.<br />

H<strong>CP</strong>167E The mask is invalid for the specified<br />

data range.<br />

Explanation: You issued the TRACE GPR comm<strong>and</strong><br />

specifying a DATA range <strong>and</strong> MASK value. When the<br />

MASK value was ANDed with both values in the DATA<br />

range, the lower limit of the resulting range was greater<br />

than the upper limit.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not executed;<br />

system operation continues.<br />

User Response: Reissue the comm<strong>and</strong> specifying a<br />

valid mask.<br />

H<strong>CP</strong>170E <strong>System</strong> name exceeds storage size;<br />

{nnnnnnnnK|nnnnM} required<br />

Explanation: The NSS (name) specified requires a<br />

guest real storage size larger than that defined for the<br />

virtual machine.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not executed;<br />

system operation continues.<br />

User Response: Redefine the virtual machine storage<br />

size using the DEFINE comm<strong>and</strong>, then reissue the<br />

comm<strong>and</strong> with the required storage size.<br />

H<strong>CP</strong>174E Paging I/O error; IPL failed<br />

H<strong>CP</strong>161I H<strong>CP</strong>177E<br />

Explanation: An I/O error occurred while the system<br />

was attempting to read a page from a direct access<br />

storage device.<br />

<strong>System</strong> Action: The IPL or DIAGNOSE X'64' failed.<br />

User Response: Reissue the IPL or DIAGNOSE X'64'<br />

comm<strong>and</strong>. If the failure persists, notify your system<br />

operator.<br />

Programmer Response: Resave the segment or<br />

system that failed. A possible cause of the condition is a<br />

bad DASD pack. If another DASD pack is available, use<br />

it to retry the IPL. If the problem persists, contact your<br />

<strong>IBM</strong> Support Center personnel to diagnose <strong>and</strong> correct<br />

the software error.<br />

H<strong>CP</strong>177E Your PARM data exceeds the limit of<br />

nn characters. Correct your data string<br />

<strong>and</strong> reissue the IPL comm<strong>and</strong>.<br />

Explanation: The PARM option on your IPL statement<br />

is followed by a parameter string that exceeds the limit<br />

of characters than can be passed to the system to be<br />

IPLed. The value of nn specifies the maximum length of<br />

the string that can be passed. The largest value nn can<br />

be is 64. If the value of nn is less than 64, the named<br />

saved system specified by the IPL comm<strong>and</strong> was<br />

defined by your installation with a PARMREGS range of<br />

less than 16 registers.<br />

Chapter 3. <strong>System</strong> <strong>Messages</strong> 153