H<strong>CP</strong>2869I H<strong>CP</strong>2877E<br />

If the format operation should continue, answer YES.<br />

Otherwise, answer NO.<br />

H<strong>CP</strong>2869I CSE XLINK FORMAT COMPLETE<br />

Explanation: The XLINK FORMAT comm<strong>and</strong><br />

completed without errors.<br />

<strong>System</strong> Action: <strong>System</strong> processing continues.<br />

User Response: None.<br />

H<strong>CP</strong>2870E ERROR nnn ON CMSSTOR CALL<br />

Explanation: The cross-system link facility utility<br />

program could not obtain enough free storage to<br />

complete the requested function. The error code nnn is<br />

the code received from the CMSSTOR macro. See<br />

z/<strong>VM</strong>: CMS Comm<strong>and</strong>s <strong>and</strong> Utilities Reference manual<br />

for more information on the CMSSTOR error messages.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not processed.<br />

User Response: You may need more available CMS<br />

free storage. The cross-system link facility utility<br />

program needs enough storage to contain all of the<br />

CSE map records at the same time. If you are<br />

displaying or formatting a track with many large map<br />

records, you may need to increase your available free<br />

storage. Possible methods of increasing free storage<br />

include defining a larger virtual machine with the <strong>CP</strong><br />

DEFINE STOR comm<strong>and</strong>, or freeing some currently<br />

allocated storage by releasing accessed disks or using<br />

the NUCXDROP comm<strong>and</strong> to cancel nucleus<br />

extensions <strong>and</strong> release the storage occupied by the<br />

corresponding program.<br />

H<strong>CP</strong>2871E INVALID OPTION: option<br />

Explanation: The specified option option is invalid.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not processed.<br />

User Response: Reenter the comm<strong>and</strong> with valid<br />

options.<br />

H<strong>CP</strong>2872E COMMAND LINE IS TOO LONG FOR<br />

<strong>CP</strong>. <strong>CP</strong> CAN ACCEPT NO MORE THAN<br />

240 CHARACTERS - YOUR COMMAND<br />

WAS nnn CHARACTERS IN LENGTH<br />

Explanation: The length of the XLINK comm<strong>and</strong> that<br />

was entered exceeds 240 characters <strong>and</strong> cannot be<br />

passed from the cross-system link facility utility program<br />

to <strong>CP</strong>. The nnn variable is the actual length of the<br />

comm<strong>and</strong> entered.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not processed.<br />

User Response: Reenter the comm<strong>and</strong> with fewer<br />

parameters. If necessary, enter the comm<strong>and</strong> more than<br />

once.<br />

324 z/<strong>VM</strong>: <strong>System</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong> — <strong>CP</strong><br />

H<strong>CP</strong>2873E MISSING OR INVALID PARAMETER OR<br />

OPTION<br />

Explanation: One of the parameters or options is<br />

missing or invalid.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not processed.<br />

User Response: Reenter the comm<strong>and</strong> with valid<br />

parameters <strong>and</strong> options.<br />

H<strong>CP</strong>2874E {Device vdev|Volume volid} is not a<br />

CKD or ECKD DASD device.<br />

Explanation: The virtual device or volume specified is<br />

not a CKD or ECKD DASD. CSE supports only CKD<br />

<strong>and</strong> ECKD DASD. The requested function cannot be<br />

completed.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not processed.<br />

User Response: Make sure that the device you want<br />

to address is a CKD or ECKD DASD. Then reenter the<br />

comm<strong>and</strong>.<br />

H<strong>CP</strong>2876I VOLUME volid WAS FORMATTED FOR<br />

CSE ON mm/dd/yy AT hh:mm:ss BY<br />

USER userid AT SYSTEM sysname<br />

Explanation: The above message is followed by this<br />

message:<br />

-CYL- READ/WRITE FLAGS ON volid (CYL=c<br />

TRK=t RECL=l RECS=r SYSTEMS=s)<br />

ccc mode sysname2<br />

- or -<br />

--- NO LINK FLAGS ON THIS VOLUME<br />

This message is issued when the XLINK DISPLAY<br />

function is requested. It informs you when <strong>and</strong> by whom<br />

the volume was formatted for CSE use.<br />

<strong>System</strong> Action: The system continues to process the<br />

comm<strong>and</strong>.<br />

User Response: None.<br />

H<strong>CP</strong>2877E EITHER NOT A CSE VOLUME, OR CSE<br />

DATA IS NOT ON CYL ccccc TRK tt<br />

Explanation: The volume for which you requested an<br />

XLINK DISPLAY may not be a CSE-controlled volume.<br />

There is no valid CSE data on cylinder ccccc, track tt.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not processed.<br />

User Response: Make sure that:<br />

v The correct CSELVOL INCLUDE list was used<br />

v The volume was correctly formatted for CSE<br />

v The parameters specified on the CSELVOL INCLUDE<br />

list embedded in the cross-system link facility utility<br />

program were the same as those used when the<br />

volume was formatted for CSE.