H<strong>CP</strong>2752E Exit {number exit does|numbers<br />

[exit1-exit2] do} not exist<br />

Explanation: An unknown <strong>CP</strong> exit point number (or a<br />

range of unknown <strong>CP</strong> exit point numbers) was specified<br />

on one of the following comm<strong>and</strong>s:<br />

v ASSOCIATE EXIT<br />

v DISABLE EXITS<br />

v DISASSOCIATE<br />

v ENABLE EXITS<br />

v LOCATE XITBK<br />

v QUERY EXITS.<br />

Most variations of this message will display the<br />

unknown <strong>CP</strong> exit point numbers that were specified on<br />

the comm<strong>and</strong>. If this message does not display any<br />

numbers, then you do not have any <strong>CP</strong> exit points<br />

defined on your system.<br />

<strong>System</strong> Action: <strong>CP</strong> rejects the comm<strong>and</strong>; system<br />

operation continues.<br />

User Response: Enter the comm<strong>and</strong> again <strong>and</strong><br />

specify an existing <strong>CP</strong> exit point number or a range of<br />

existing <strong>CP</strong> exit point numbers.<br />

If there are no <strong>CP</strong> exit points established on your<br />

system, which would be done by ASSOCIATE EXIT,<br />

then you cannot change or interrogate them or their<br />

control blocks.<br />

H<strong>CP</strong>2753E The {specified|requested} control entry<br />

point caused <strong>CP</strong>XLOAD to fail<br />

reason<br />

Explanation: <strong>CP</strong> did not load the customer-written <strong>CP</strong><br />

routines because there was a problem with the entry<br />

point specified with the CONTROL oper<strong>and</strong>. The<br />

problem occurred because of the specified reason:<br />

Cannot find the specified entry point<br />

<strong>CP</strong> tried to locate the entry point name<br />

specified by the CONTROL keyword, but could<br />

not find it. Perhaps the entry point name was<br />

misspelled or had not been loaded.<br />

It is a TEMPORARY entry point<br />

<strong>CP</strong> did locate the entry point name specified by<br />

the CONTROL keyword. Unfortunately, the<br />

entry point name was loaded by a prior<br />

<strong>CP</strong>XLOAD that specified TEMPORARY. A<br />

TEMPORARY <strong>CP</strong>XLOAD entry point name<br />

may not be used as the control entry point<br />

name for a different <strong>CP</strong>XLOAD request.<br />

The specified entry point was marked for deletion<br />

The entry point name specified by the<br />

CONTROL keyword was marked for deletion<br />

by a ".DEL" TEXT-file statement or by a<br />

CHANGE directive.<br />

H<strong>CP</strong>2752E H<strong>CP</strong>2755E<br />

Cannot call the specified entry point<br />

<strong>CP</strong> tried to call the entry point name, but the<br />

attempt failed. This could be because there<br />

exists a mismatch between the related ICRBK<br />

<strong>and</strong> ICLBK control blocks, or other internal<br />

mismatch.<br />

The specified entry point rejected the <strong>CP</strong>XLOAD<br />

request with return code nn<br />

<strong>CP</strong> called the entry point name <strong>and</strong> the entry<br />

point returned a nonzero return code of nn.<br />

Any nonzero return code directs <strong>CP</strong> to reject<br />

the request.<br />

<strong>System</strong> Action: <strong>CP</strong> rejects the comm<strong>and</strong>; system<br />

operation continues.<br />

User Response: Your action depends on the indicated<br />

reason:<br />

Cannot find the specified entry point<br />

Make sure that the specified entry point name<br />

is correct.<br />

It is a TEMPORARY entry point<br />

Make sure that the specified entry point name<br />

is loaded PERMANENT.<br />

The specified entry point was marked for deletion<br />

Make sure that the specified entry point name<br />

is not marked to be deleted so that <strong>CP</strong> can call<br />

it.<br />

Cannot call the specified entry point<br />

Investigate why <strong>CP</strong> could not call the entry<br />

point. You may need to establish TRSOURCE<br />

tracing or even cause a system dump.<br />

The specified entry point rejected the <strong>CP</strong>XLOAD<br />

request with return code nn<br />

Investigate why the entry point rejected the<br />

request.<br />

H<strong>CP</strong>2754E Language xxxxx for Component yyy<br />

does not exist<br />

Explanation: A language <strong>and</strong> component was<br />

specified on the DISASSOCIATE MESSAGES<br />

comm<strong>and</strong> that is not already associated with an entry<br />

point.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not processed.<br />

User Response: Use the QUERY <strong>CP</strong>LANGUAGE<br />

ASSOCIATED comm<strong>and</strong> to determine the correct<br />

language <strong>and</strong> component identifier then enter the<br />

comm<strong>and</strong> again with the corrected information.<br />

H<strong>CP</strong>2755E Encountered I/O error while loading<br />

cards<br />

Explanation: An I/O error occurred while <strong>CP</strong> was<br />

loading cards from the customer-written <strong>CP</strong> routines into<br />

<strong>CP</strong> storage.<br />

<strong>System</strong> Action: <strong>CP</strong> rejects the <strong>CP</strong>XLOAD comm<strong>and</strong><br />

Chapter 3. <strong>System</strong> <strong>Messages</strong> 301