updated <strong>and</strong> processing continues.<br />

User Response: None<br />

H<strong>CP</strong>9951E Invalid LKFAC configuration name<br />

entered<br />

Explanation: The Multi-Path Lock Facility (MPLF)<br />

RPQ simulation configuration name specified on the<br />

SET LKFAC comm<strong>and</strong>:<br />

v contains more than 8 characters, or<br />

v does not consist of alphanumeric characters in the<br />

range A to Z.<br />

<strong>System</strong> Action: The request is ignored.<br />

User Response: Re-enter the SET LKFAC comm<strong>and</strong><br />

using a 1- to 8-character alphanumeric configuration<br />

name.<br />

H<strong>CP</strong>9952E Maximum (8) users assigned to LKFAC<br />

configuration config_name<br />

Explanation: The maximum number of users allowed<br />

to be connected to the Multi-Path Lock Facility (MPLF)<br />

RPQ simulation configuration is already assigned. The<br />

maximum number allowed is 8.<br />

<strong>System</strong> Action: The request is ignored.<br />

User Response: None.<br />

H<strong>CP</strong>9954E Maximum LKFAC configurations<br />

defined, config_name not created<br />

Explanation: The configuration name table does not<br />

contain an available entry to hold the new Multi-Path<br />

Lock Facility (MPLF) RPQ simulation configuration. The<br />

maximum number of configurations is 250.<br />

<strong>System</strong> Action: The request is ignored.<br />

User Response: None.<br />

H<strong>CP</strong>9955I No change, LKFAC configuration same<br />

as entered<br />

Explanation: There is no difference between the<br />

specified name <strong>and</strong> the name currently in use for the<br />

Multi-Path Lock Facility (MPLF) RPQ simulation<br />

configuration.<br />

<strong>System</strong> Action: The request is ignored.<br />

User Response: Re-enter the SET LKFAC request<br />

with a different name to join a new configuration.<br />

Otherwise, no response is necessary.<br />

H<strong>CP</strong>9961E LKFAC CONFIGURATION config_name<br />

CANNOT BE FOUND<br />

Explanation: The QUERY processor cannot locate the<br />

specified Multi-Path Lock Facility (MPLF) RPQ<br />

simulation configuration name in the configuration name<br />

table.<br />

<strong>System</strong> Action: The request is ignored.<br />

User Response: Re-enter the QUERY LKFAC request<br />

with the correct configuration name. Use QUERY<br />

LKFAC ALL to display a list of active configuration<br />

names.<br />

H<strong>CP</strong>9962E userid not attached to a LKFAC<br />

configuration<br />

Explanation: The QUERY LKFAC comm<strong>and</strong> was<br />

issued without a name specified for the Multi-Path Lock<br />

Facility (MPLF) RPQ simulation configuration. When no<br />

name is specified, the default is normally a display of<br />

information for the user’s attached configuration.<br />

However, in this case the user is not attached to any<br />

configuration.<br />

<strong>System</strong> Action: The request is ignored.<br />

User Response: Re-enter the QUERY LKFAC request<br />

with the correct configuration name. Use QUERY<br />

LKFAC ALL to display a list of active configuration<br />

names.<br />

H<strong>CP</strong>9963E No LKFAC configuration defined<br />

Explanation: A QUERY LKFAC was issued, but the<br />

configuration name table was not allocated yet.<br />

Therefore, the Multi-Path Lock Facility (MPLF) RPQ<br />

simulation configuration cannot be added to the table.<br />

<strong>System</strong> Action: The request is ignored.<br />

User Response: None.<br />

H<strong>CP</strong>9951E H<strong>CP</strong>9965E<br />

H<strong>CP</strong>9964E User not authorized to use LKFAC<br />

simulation support<br />

Explanation: A SET LKFAC comm<strong>and</strong> was entered,<br />

but the user was not authorized to use via the OPTION<br />

LKFAC user directory control statement.<br />

<strong>System</strong> Action: The request is ignored.<br />

User Response: To use the Multi-Path Lock Facility<br />

(MPLF) RPQ simulation support the user must be<br />

authorized to use the SET LKFAC comm<strong>and</strong> through<br />

specification in the OPTION LKFAC statement in their<br />

user directory entry.<br />

H<strong>CP</strong>9965E Unable to write into one of the<br />

IUCV/APPC interrupt buffers.<br />

Explanation: A machine check or protection exception<br />

was detected while attempting to write into one of the<br />

IUCV/APPC interrupt buffers. Possible causes include:<br />

v A DCSS has overlaid one of the interrupt buffers.<br />

v A paging error was detected when attempting to page<br />

in one of the interrupt buffers.<br />

Chapter 3. <strong>System</strong> <strong>Messages</strong> 469