v The real device is offline.<br />

Vary the device on-line, <strong>and</strong> issue a SET VSWITCH<br />

comm<strong>and</strong> with the CONNECT option.<br />

v Error errorcode attaching devices to userid.<br />

Contact the <strong>IBM</strong> Support Center.<br />

v OSA Express device device stall detected.<br />

Determine if any hardware conditions exist that could<br />

cause the problem. If any exist, correct them.<br />

Otherwise, contact the <strong>IBM</strong> Support Center.<br />

v T<strong>CP</strong>/IP controller userid is attempting to restart<br />

the device<br />

Use the QUERY VSWITCH comm<strong>and</strong> to show the<br />

updated status. If the status does not change,<br />

examine the console for the virtual switch controller<br />

for error messages related to the device.<br />

H<strong>CP</strong>2833E {Error ’errcode’X removing IP address<br />

ipaddr for VSWITCH SYSTEM<br />

switchnm|Error ’errcode’X adding IP<br />

address ipaddr for VSWITCH SYSTEM<br />

switchnm[IP Address is already in use<br />

on the LAN.|IP address is already<br />

registered.|Adapter IP address table is<br />

full.]}<br />

Explanation: The T<strong>CP</strong>/IP Controller received an error<br />

when attempting to add or remove an IP address.<br />

v For the message formats containing IP address is<br />

already in use on the LAN or IP address already<br />

registered, an IP address was provided by a guest<br />

host which has coupled to the switchnm. However,<br />

that IP address is already in use on the real<br />

hardware LAN segment to which the virtual switch is<br />

connected.<br />

v For the message format containing Adapter IP<br />

address table is full, the guest hosts coupled to the<br />

virtual switch have together used more IP addresses<br />

than allowed by the adapter.<br />

v For remaining message formats, an unexpected error<br />

was received.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues, but the<br />

IP address table was not changed.<br />

v For the message format containing IP address is<br />

already in use on the LAN, the address is<br />

registered for use among guest hosts coupled to the<br />

virtual switch. However, it is not registered for use by<br />

members of the real hardware LAN segment to which<br />

the virtual switch is connected using an OSA Express<br />

device.<br />

<strong>System</strong> Programmer Response:<br />

v For the message formats containing IP address is<br />

already in use on the LAN, verify the IP address<br />

assignments for the guest hosts connected to the<br />

virtual switch for conflicts with those in use on the<br />

real hardware LAN segment. Use the Query<br />

VSWITCH DETAILS comm<strong>and</strong> to display the IP<br />

address assignments for the virtual switch, paying<br />

particular attention to those marked Local or<br />

Disabled.<br />

v For the message format containing Adapter IP<br />

address table is full, examine the IP address<br />

assignments for the guest hosts <strong>and</strong> remove any that<br />

are not required. If that is not possible, create an<br />

additional virtual switch with a separate connection to<br />

the real hardware LAN segment.<br />

v For remaining message formats, contact the <strong>IBM</strong><br />

Support Center.<br />

H<strong>CP</strong>2834E {Error ’errcode’X adding IP multicast<br />

address ipaddr for VSWITCH SYSTEM<br />

switchnm|Error ’errcode’X adding IP<br />

multicast address ipaddr for VSWITCH<br />

SYSTEM switchnm IP multicast table is<br />

full.|Error ’errcode’X removing IP<br />

multicast address ipaddr for VSWITCH<br />

SYSTEM switchnm}<br />

Explanation: The T<strong>CP</strong>/IP Controller received an error<br />

when attempting to add or remove a multicast IP<br />

address in the adapter’s IP multicast address table.<br />

v For the message format containing IP multicast<br />

table is full, the guest hosts coupled to the Virtual<br />

Switch have together used more IP addresses than<br />

allowed by the adapter.<br />

v For remaining message formats, an unexpected error<br />

was received.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues, but the<br />

IP address table was not changed.<br />

<strong>System</strong> Programmer Response:<br />

v For the message format containing IP multicast<br />

table is full, examine the IP address assignments for<br />

the guest hosts <strong>and</strong> remove any that are not<br />

required. If that is not possible, create an additional<br />

Virtual Switch with a separate connection to the real<br />

hardware LAN segment.<br />

v For remaining message formats, contact the <strong>IBM</strong><br />

Support Center.<br />

H<strong>CP</strong>2835E CONTROLLER userid does not exist.<br />

Explanation: The specified controller userid is not<br />

currently defined as a controller.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

<strong>System</strong> Programmer Response: Correct the<br />

controller name <strong>and</strong> reissue the QUERY CONTROLLER<br />

comm<strong>and</strong>.<br />

H<strong>CP</strong>2836E VLAN was not found.<br />

H<strong>CP</strong>2833E H<strong>CP</strong>2836E<br />

Explanation: An active connection was not found<br />

matching the specified VLAN ID.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

Chapter 3. <strong>System</strong> <strong>Messages</strong> 319