28.12.2012 Views

z/VM: System Messages and Codes Š CP - z/VM - IBM

z/VM: System Messages and Codes Š CP - z/VM - IBM

z/VM: System Messages and Codes Š CP - z/VM - IBM

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CMS that is <strong>VM</strong>/ESA 2.1.0 or later.<br />

HCQ071E Definition for name not found<br />

Explanation: The definition for the requested byte,<br />

field, or control block could not be found in the definition<br />

file.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Ensure you have specified the<br />

correct name of the byte or control block. If this is not<br />

an <strong>IBM</strong>-supplied <strong>CP</strong> control block, then consider adding<br />

the definition to the control block definition file (see<br />

"Appendix D" of the z/<strong>VM</strong>: <strong>VM</strong> Dump Tool). If this is an<br />

<strong>IBM</strong>-supplied <strong>CP</strong> control block, contact your <strong>IBM</strong><br />

Support Center.<br />

HCQ072E Definition for the following fields not<br />

found<br />

Explanation: The definition of the indicated fields<br />

could not be found in the definition file.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Be sure you have specified the<br />

correct names of the fields. If this is not an<br />

<strong>IBM</strong>-supplied <strong>CP</strong> control block, then consider adding the<br />

definition of the fields to the control block definition file<br />

(see "Appendix D" of the z/<strong>VM</strong>: <strong>VM</strong> Dump Tool). If these<br />

fields are part of an <strong>IBM</strong>-supplied <strong>CP</strong> control block,<br />

contact your <strong>IBM</strong> Support Center.<br />

HCQ073E blockname not found, <strong>CP</strong> EXIT<br />

information not available<br />

Explanation: The control block indicated by<br />

blockname is required to find the <strong>CP</strong> EXIT information<br />

in the dump <strong>and</strong> could not be located. If this is a soft<br />

abend dump, then probably the required part of storage<br />

was not included in the dump.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: The information is not available. Try<br />

another approach to find the information you are looking<br />

for.<br />

HCQ074E Trace entry at address is non-st<strong>and</strong>ard<br />

Explanation: A trace entry other than types 74 or 75<br />

has been encountered. This trace entry is most likely<br />

produced by non-<strong>IBM</strong> code <strong>and</strong> cannot be interpreted<br />

by the <strong>VM</strong> Dump Tool.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Look at the data in the vicinity of the<br />

failing address. Then determine the address of the next<br />

valid trace entry (it will start with 74 or 75). Reissue the<br />

TRACE subcomm<strong>and</strong> starting with that address.<br />

HCQ075E Error getting blockname<br />

Explanation: The MAPIUCV macro encountered an<br />

error in trying to fetch the control block indicated by<br />

blockname from the dump. This probably indicates an<br />

error in either the requested subcomm<strong>and</strong> or macro, or<br />

in the <strong>CP</strong> tables used to control IUCV.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Try to find the required information<br />

from another source. If the problem persists, contact<br />

your <strong>IBM</strong> Support Center.<br />

HCQ076E Error in byte definition - xxxxxxxx<br />

yyyyyyyy<br />

Explanation: A structural error was found in the<br />

control block definition file for the requested byte<br />

indicated by xxxxxxxx. The data indicated by yyyyyyyy<br />

should have been ’*BITS’ or ’*CODE’ but was not.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Be sure you have specified the<br />

correct name of the byte. If this is not an <strong>IBM</strong>-supplied<br />

<strong>CP</strong> control block, then consider adding the definition of<br />

the fields to the control block definition file (see<br />

"Appendix D" of the z/<strong>VM</strong>: <strong>VM</strong> Dump Tool). If this byte<br />

is part of an <strong>IBM</strong>-supplied <strong>CP</strong> control block, contact<br />

your <strong>IBM</strong> Support Center.<br />

HCQ077W Length 0 not allowed, set to n<br />

Explanation: A length value of zero was found but is<br />

not allowed.<br />

<strong>System</strong> Action: The length value is set to the value<br />

indicated <strong>and</strong> processing continues.<br />

User Response: Enter the subcomm<strong>and</strong> again with a<br />

proper length value.<br />

HCQ078E Error getting storage<br />

HCQ071E HCQ078E<br />

Explanation: An error was returned when the <strong>VM</strong><br />

Dump Tool tried to acquire storage to hold map<br />

information or a field or control block definition.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Try running the <strong>VM</strong> Dump Tool in a<br />

larger virtual machine. If the requested control block is<br />

installation-defined, be sure the definition is correct. If<br />

the requested control block is in <strong>CP</strong> <strong>and</strong> is <strong>IBM</strong>-supplied<br />

<strong>and</strong> the problem persists, contact your <strong>IBM</strong> Support<br />

Center.<br />

Chapter 3. <strong>System</strong> <strong>Messages</strong> 479

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!