HCQ087E Overflow<br />

Explanation: The output of the HEX subcomm<strong>and</strong> is<br />

too large to fit into 32 bits.<br />

<strong>System</strong> Action: The operation terminates.<br />

User Response: Ensure the input values are correct.<br />

Use smaller values.<br />

HCQ088E Not within a module - address<br />

Explanation: The address given to the MAP<br />

subcomm<strong>and</strong> could not be associated with any <strong>CP</strong><br />

module in the dump.<br />

<strong>System</strong> Action: The operation terminates.<br />

User Response: Be sure the address is correct <strong>and</strong><br />

retry the subcomm<strong>and</strong>.<br />

HCQ089E High order part of fieldname not zero -<br />

yyyyyyyy<br />

Explanation: This probably indicates an error in either<br />

the requested subcomm<strong>and</strong> or macro or in the <strong>CP</strong><br />

tables in the dump used for address translation. The<br />

high order part of the field indicated by fieldname was<br />

not zero. The contents of the byte are indicated by yy.<br />

This condition was not anticipated <strong>and</strong> is not<br />

meaningful.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Be sure the requested address is<br />

correct. If the problem persists, contact your <strong>IBM</strong><br />

Support Center.<br />

HCQ090I No fields found which match this<br />

criteria<br />

Explanation: This is issued when the BLOCK macro<br />

is invoked with specific displacements, <strong>and</strong> no fields<br />

were found in this block which reference any of the<br />

displacements specified.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Be sure the requested displacement<br />

is correct. To produce a list of all of the fields in a<br />

particular control block, invoke the BLOCK macro<br />

without the FIELDS option.<br />

HCQ091E Not a user ID - xxxxxxxx<br />

Explanation: The requested subcomm<strong>and</strong> or macro<br />

accepts only a user ID as input. The input value<br />

indicated by xxxxxxxx could not be identified as a user<br />

ID.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again using a correct user ID.<br />

HCQ092E Unrecognized type - type<br />

HCQ087E HCQ096E<br />

Explanation: The indicated input was expected to be<br />

a trace type request, but was not recognized.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: See HELP for the TRACE<br />

subcomm<strong>and</strong> to determine the allowable values of<br />

TYPE, <strong>and</strong> enter the subcomm<strong>and</strong> or macro again<br />

using a correct TYPE value.<br />

HCQ093E Bad Entry Point name or address -<br />

xxxxxxxx<br />

Explanation: The input was expected to be a module<br />

or entry point name, but such a module or entry point<br />

could not be located in the dump. If the dump is a soft<br />

abend dump, the storage containing this module or<br />

entry point was probably not included in the dump.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again using a correct module or entry point name.<br />

HCQ094E Address cannot be above FC0 in page<br />

- addr<br />

Explanation: The last X'40' bytes in a trace table page<br />

are linkage, so a starting or ending address above<br />

X'FC0' in a trace table page is not allowed.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again using a smaller displacement in the trace table<br />

page.<br />

HCQ095E addrtype address cannot be 0<br />

Explanation: A value of zero specified to the TRACE<br />

subcomm<strong>and</strong> as an address is not meaningful <strong>and</strong> is<br />

not allowed.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again using a correct address.<br />

HCQ096E Not a valid <strong>VM</strong>DBK address or userid -<br />

xxxxxxxx<br />

Explanation: The indicated input was expected to be<br />

the address of a <strong>VM</strong>DBK or the user ID of a logged on<br />

user, but was found to be neither.<br />