28.12.2012 Views

z/VM: System Messages and Codes Š CP - z/VM - IBM

z/VM: System Messages and Codes Š CP - z/VM - IBM

z/VM: System Messages and Codes Š CP - z/VM - IBM

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

HCQ006W HCQ014E<br />

HCQ006W Extra parameter ignored - parameter<br />

Explanation: The indicated parameter was found, but<br />

no more parameters are expected or allowed for this<br />

subcomm<strong>and</strong> or macro.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro continues<br />

processing.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again using the correct parameters.<br />

HCQ007E <strong>VM</strong> Dump Tool comm<strong>and</strong> terminated,<br />

error in dump size indicator<br />

Explanation: The value of the indicator of storage size<br />

in the dump is zero, which is not a valid value. The <strong>VM</strong><br />

Dump Tool uses this field to control the sizes of some<br />

tables, <strong>and</strong> can not continue without a valid value.<br />

<strong>System</strong> Action: The <strong>VM</strong> Dump Tool terminates.<br />

User Response: Check to make sure this is a dump<br />

file. If the problem persists, contact the <strong>IBM</strong> Support<br />

Center for assistance.<br />

HCQ008W Wrapped past page 0<br />

Explanation: The SCROLLUP subcomm<strong>and</strong><br />

parameters would cause the display to continue<br />

backward past page 0 of storage.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> terminates.<br />

User Response: Enter the subcomm<strong>and</strong> again with a<br />

valid address.<br />

HCQ009E parameter is negative or zero<br />

Explanation: The indicated parameter is a negative or<br />

zero value when a positive value is required.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> terminates.<br />

User Response: Enter the subcomm<strong>and</strong> again with<br />

the correct parameters.<br />

HCQ010E Can SCROLL only after a full length<br />

display<br />

Explanation: The SCROLL subcomm<strong>and</strong> can be used<br />

only after a full length display, one for which no length<br />

was specified.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> terminates.<br />

User Response: Use the DISPLAY subcomm<strong>and</strong> first<br />

with no length parameter.<br />

HCQ011E Duplicate oper<strong>and</strong> - oper<strong>and</strong><br />

Explanation: The indicated term has been<br />

encountered twice <strong>and</strong> is allowed only once.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

472 z/<strong>VM</strong>: <strong>System</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong> — <strong>CP</strong><br />

User Response: Enter the subcomm<strong>and</strong> again without<br />

using duplicate parameters.<br />

HCQ011W Duplicate oper<strong>and</strong> ignored - oper<strong>and</strong><br />

Explanation: The indicated term has been<br />

encountered twice <strong>and</strong> is allowed only once.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro continues<br />

processing.<br />

User Response: Enter the subcomm<strong>and</strong> again without<br />

using duplicate parameters.<br />

HCQ012E Conflicting oper<strong>and</strong> - oper<strong>and</strong><br />

Explanation: The indicated parameter conflicts with<br />

another parameter that has already been found.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Use the manual or HELP to find the<br />

conflict, correct it, <strong>and</strong> enter the subcomm<strong>and</strong> or macro<br />

again.<br />

HCQ012W Conflicting oper<strong>and</strong> ignored - oper<strong>and</strong><br />

Explanation: The indicated parameter conflicts with<br />

another parameter that has already been found.<br />

<strong>System</strong> Action: Processing continues.<br />

User Response: Use the manual or HELP to find the<br />

conflict, correct it, <strong>and</strong> enter the subcomm<strong>and</strong> or macro<br />

again.<br />

HCQ013E Base not known - xxxxxxxx<br />

Explanation: The base value specified to the<br />

GREGBASE subcomm<strong>and</strong> is not recognized. It must be<br />

either a named save area or an address.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> terminates.<br />

User Response: Enter the subcomm<strong>and</strong> again with<br />

the correct parameters.<br />

HCQ014E File fn ft not found<br />

Explanation: The named file is required for the<br />

requested function but could not be found.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Locate the required file, be sure it is<br />

accessible to the <strong>VM</strong> Dump Tool <strong>and</strong> enter the<br />

subcomm<strong>and</strong> or macro again.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!