28.12.2012 Views

z/VM: System Messages and Codes Š CP - z/VM - IBM

z/VM: System Messages and Codes Š CP - z/VM - IBM

z/VM: System Messages and Codes Š CP - z/VM - IBM

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

user ID that is in the directory or contact your system<br />

administrator to obtain the necessary authorization.<br />

H<strong>CP</strong>008E Invalid spoolid - spoolid<br />

Explanation: The spool ID specified is not a valid<br />

decimal number, is larger than four digits, or is 0.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not executed;<br />

system operation continues.<br />

User Response: Reissue the comm<strong>and</strong> with a valid<br />

spool ID number.<br />

H<strong>CP</strong>009E The variations of this message are<br />

explained below.<br />

MESSAGES:<br />

v Invalid range - range<br />

v An invalid address range was specified.<br />

Explanation: You did not specify the range of<br />

addresses or registers correctly. For example, you may<br />

have specified the ending address as less than the<br />

starting address, or you may have specified too many<br />

ranges.<br />

<strong>System</strong> Action: <strong>CP</strong> does not execute the comm<strong>and</strong>;<br />

system operation continues.<br />

User Response: Issue the comm<strong>and</strong> again <strong>and</strong><br />

specify a valid range.<br />

H<strong>CP</strong>010E The variations of this message are<br />

explained below.<br />

MESSAGES:<br />

v Invalid register - register<br />

Explanation: The register you specified is:<br />

– Outside the range of 0 through 15<br />

– Outside the hexadecimal range of 0 through F<br />

– Not a 0, 2, 4, or 6 for a floating-point register. (If<br />

floating-point extensions are installed, you can<br />

have 0-15 floating-point registers.)<br />

v Invalid register - not specified.<br />

Explanation: The register prefix value was specified<br />

(for example, G), but a register number was not<br />

specified.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not executed.<br />

<strong>System</strong> operation continues.<br />

User Response: Reissue the comm<strong>and</strong>. Specify a<br />

valid register.<br />

H<strong>CP</strong>011E Invalid device type - userid vdev<br />

Explanation: The device type is invalid.<br />

If this is the COUPLE comm<strong>and</strong>, the device that was<br />

specified is not a virtual channel-to-channel adapter.<br />

If this is a DIAL comm<strong>and</strong>, the device specified is not a<br />

virtual line.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not executed;<br />

system operation continues.<br />

User Response: Make sure that the device is the<br />

correct type for the function <strong>and</strong> reissue the comm<strong>and</strong>.<br />

H<strong>CP</strong>012E Invalid PSW - psw<br />

Explanation: The program status word (PSW)<br />

specified by the STORE comm<strong>and</strong> is invalid. For<br />

instance, a valid PSW for an XA virtual machine is<br />

defined by the architecture to have certain bits off.<br />

<strong>System</strong> Action: <strong>System</strong> continues operation.<br />

User Response: Change the PSW to a valid format<br />

for the mode of the virtual machine. If you do not do<br />

this, attempting to run the virtual machine with an invalid<br />

PSW causes the <strong>CP</strong> dispatcher to issue an invalid PSW<br />

message.<br />

H<strong>CP</strong>013E Conflicting option - option<br />

H<strong>CP</strong>008E H<strong>CP</strong>016E<br />

Explanation: The function required by the given option<br />

is incompatible with a previously specified option. This<br />

may occur if the same option is specified twice in the<br />

same comm<strong>and</strong>.<br />

This message is issued if the DCSS parameter is<br />

specified on the <strong>VM</strong>DUMP comm<strong>and</strong> for an address<br />

space that does not have a saved system associated<br />

with it.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not executed;<br />

system operation continues.<br />

User Response: Reissue the comm<strong>and</strong> with valid<br />

options.<br />

H<strong>CP</strong>015E Comm<strong>and</strong> not valid before LOGON:<br />

comm<strong>and</strong><br />

Explanation: A user has attempted to issue either the<br />

DIAL or MESSAGE comm<strong>and</strong>. During system<br />

installation the customer can flag these comm<strong>and</strong>s so<br />

that they cannot be issued prior to logging on the<br />

system. The comm<strong>and</strong> was the <strong>CP</strong> comm<strong>and</strong> that was<br />

issued by the user.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

User Response: If the MESSAGE comm<strong>and</strong> was<br />

issued, the user should logon the system <strong>and</strong> then<br />

reissue the comm<strong>and</strong>. There is no alternative action a<br />

user can take for the DIAL comm<strong>and</strong>.<br />

H<strong>CP</strong>016E TAG invalid for specified file type<br />

Explanation: The spool file cannot be tagged. The<br />

splink (the data buffer) does not leave space for tag<br />

information (accounting, dump, <strong>and</strong> monitor files).<br />

Chapter 3. <strong>System</strong> <strong>Messages</strong> 139

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!