H<strong>CP</strong>1781E THE option1 OPTION WAS SPECIFIED<br />

ON THE DIRECTXA COMMAND<br />

WITHOUT THE option2 OPTION.<br />

Explanation: The user invoked DIRECTXA with the<br />

MIXMSG/NOMIXMSG keyword but failed to specify the<br />

MIXED keyword.<br />

<strong>System</strong> Action: Processing is terminated, <strong>and</strong> control<br />

is returned to the caller with return code 3 in register 15.<br />

User Response: Correct the error <strong>and</strong> reenter the<br />

DIRECTXA comm<strong>and</strong>.<br />

H<strong>CP</strong>1782E THE DUPLICATE OPTION option WAS<br />

SPECIFIED ON THE DIRECTXA<br />

COMMAND.<br />

Explanation: The user invoked DIRECTXA with a<br />

duplicate option.<br />

<strong>System</strong> Action: Processing is terminated, <strong>and</strong> control<br />

is returned to the caller with return code 3 in register 15.<br />

User Response: Reenter the DIRECTXA comm<strong>and</strong><br />

with the appropriate options.<br />

H<strong>CP</strong>1783E AN OPERAND OF THE SYSAFFIN<br />

STATEMENT IS MISSING.<br />

Explanation: One or more sysafnid parameters is<br />

missing from the SYSAFFIN control statement.<br />

<strong>System</strong> Action: The failing control statement is<br />

displayed above the error message. Processing<br />

terminates <strong>and</strong> control is returned to the caller with a<br />

return code of 2 in register 15.<br />

User Response: Add the missing sysafnid to the<br />

SYSAFFIN control statement <strong>and</strong> reenter the<br />

DIRECTXA comm<strong>and</strong>.<br />

H<strong>CP</strong>1784E THE option OPTION SPECIFIED ON THE<br />

DIRECTXA COMMAND HAS AN<br />

INVALID VALUE.<br />

Explanation: The DIRECTXA comm<strong>and</strong> was entered<br />

with a value that is not valid for the indicated keyword<br />

option.<br />

<strong>System</strong> Action: Processing is terminated, <strong>and</strong> control<br />

is returned to the calling module with a return code of 3<br />

in register 15.<br />

User Response: Enter the DIRECTXA comm<strong>and</strong><br />

again with a valid value for the option. For the<br />

SYSAFNID option, specify a value from one of the<br />

DIRECTORY control statements in the USER DIRECT<br />

file. For the &SYSRES option, specify a 1- to<br />

6-character string to be used to represent the system<br />

residence volume serial.<br />

H<strong>CP</strong>1781E H<strong>CP</strong>1788E<br />

H<strong>CP</strong>1785E THE {PROFILE profname| USER<br />

userid|POOL poolid} FROM THE<br />

{PROFILE|USER|USER} STATEMENT<br />

DOES NOT MATCH THE {PROFILE<br />

profname|USER userid| POOL poolid}<br />

FROM THE INCLUDING LOAD<br />

STATEMENT.<br />

Explanation: The PROFILE name specified on the<br />

LOAD P statement must match that on the PROFILE<br />

statement. The user ID specified on the LOAD U<br />

statement must match that on the USER statement. The<br />

POOLID specified on the LOAD U statement must<br />

match that on the USER statement.<br />

<strong>System</strong> Action: The system issues this message,<br />

processing is terminated, <strong>and</strong> control is returned to the<br />

caller with return code 2 in Register 15.<br />

User Response: Correct the profile name or the user<br />

ID or the pool ID <strong>and</strong> reenter the DIRECTXA comm<strong>and</strong>.<br />

H<strong>CP</strong>1786E THE STATEMENT IS NOT VALID IN A<br />

CLUSTER DIRECTORY INDEX.<br />

Explanation: Only LOAD <strong>and</strong> comment statements<br />

are valid in the DIRECTORY INDEX file. The<br />

DIRECTORY INDEX file is the file specified on the<br />

DIRECTXA comm<strong>and</strong>.<br />

<strong>System</strong> Action: Processing is terminated, <strong>and</strong> control<br />

is returned to the caller with return code 2 in register 15.<br />

User Response: Correct the invalid control statement<br />

<strong>and</strong> reenter the DIRECTXA comm<strong>and</strong>.<br />

H<strong>CP</strong>1787E THE DIRECTORY STATEMENT DOES<br />

NOT CONTAIN THE <strong>CP</strong>UID AND<br />

SYSAFNID FIELDS.<br />

Explanation: The <strong>CP</strong>UID <strong>and</strong> SYSAFNID parameters<br />

are missing on the DIRECTORY control statement.<br />

<strong>System</strong> Action: Processing is terminated, <strong>and</strong> control<br />

is returned to the calling module with a return code of 2<br />

in register 15.<br />

User Response: Correct the DIRECTORY control<br />

statement <strong>and</strong> reenter the DIRECTXA comm<strong>and</strong>.<br />

H<strong>CP</strong>1788E THE CONFLICTING OPTION option WAS<br />

SPECIFIED ON THE DIRECTXA<br />

COMMAND.<br />

Explanation: The user entered DIRECTXA with a<br />

conflicting option.<br />

<strong>System</strong> Action: This message is issued, processing is<br />

terminated, <strong>and</strong> control is returned to the caller with<br />

return code 3 in register 15.<br />

User Response: Reenter the DIRECTXA comm<strong>and</strong><br />

with the correct options.<br />