not fill up the error log or flood the operator’s console<br />

with messages.<br />

<strong>System</strong> Action: Normal system operation continues,<br />

but without reporting system recovery errors.<br />

Operator Response: If system recovery errors have<br />

not been too frequent, <strong>and</strong> you do want to have them<br />

reported to you <strong>and</strong> recorded in the error log in the<br />

future, enter the SET MODE comm<strong>and</strong>, as follows, to<br />

enable reporting of system recovery errors once again:<br />

SET MODE RECORD<br />

H<strong>CP</strong>9108E UNEXPECTED ERROR. POSSIBLY<br />

CAUSED BY SOFTWARE.<br />

Explanation: A condition that normally produces an<br />

abend has occurred, but it occurred in the<br />

machine-check h<strong>and</strong>ler, where an abend cannot be<br />

safely issued. Therefore, system termination is being<br />

initiated directly from the machine-check h<strong>and</strong>ler rather<br />

than from the abend processor.<br />

<strong>System</strong> Action: The system stops. An automatic<br />

software re-IPL will not follow this termination.<br />

Operator Response: Notify your system support<br />

personnel.<br />

H<strong>CP</strong>9109I <strong>System</strong> operation continues.<br />

Explanation: The machine check that message<br />

H<strong>CP</strong>9101I describes, or the check-stop that message<br />

H<strong>CP</strong>610I describes, has been h<strong>and</strong>led successfully.<br />

<strong>System</strong> termination was not required.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues. If the<br />

error was a check-stop, the failed processor will soon<br />

be varied offline. If the error was a machine check, the<br />

failed processor may or may not be varied offline,<br />

depending on the severity of the error.<br />

Operator Response: None.<br />

H<strong>CP</strong>9110I Reporting will be suspended<br />

temporarily because machine checks<br />

are occurring too frequently.<br />

Explanation: In the past few minutes, machine checks<br />

have occurred frequently. In order to avoid tying up the<br />

console with error messages, machine-check reporting<br />

is being suspended for a few minutes. Recording these<br />

errors in the error log for <strong>CP</strong>EREP is also suspended.<br />

The suspension is selective. New types of errors are<br />

still reported <strong>and</strong> recorded. Also, the suspension is only<br />

temporary. In a few minutes the system returns<br />

(unannounced) to normal operation unless the frequent<br />

errors persist.<br />

<strong>System</strong> Action: Normal operation of the system<br />

continues, but fewer errors are being reported.<br />

Operator Response: If the problem persists, contact<br />

your system support personnel.<br />

Programmer Response: Contact your <strong>IBM</strong> Support<br />

Center personnel to diagnose <strong>and</strong> correct the hardware<br />

problem.<br />

H<strong>CP</strong>9111I An exp<strong>and</strong>ed storage error has<br />

occurred.<br />

Explanation: A machine check occurred in exp<strong>and</strong>ed<br />

storage, or, an exp<strong>and</strong>ed storage operation returned a<br />

non-zero condition code.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

Operator Response: This is probably a hardware<br />

error. If you need assistance, contact your <strong>IBM</strong><br />

representative.<br />

H<strong>CP</strong>9150E A(n) {equipment|receiver} check has<br />

occurred because the signalling facility<br />

for processor nn is damaged.<br />

Explanation: A SIGP SENSE showed either an<br />

equipment check or a receiver check. These checks<br />

indicate that the signal has failed. The unresponsive<br />

processor detection function detected this situation.<br />

<strong>System</strong> Action: The message is repeated every ten<br />

seconds until the condition is corrected or the failing<br />

processor is varied offline.<br />

User Response: None.<br />

Operator Response: Contact your <strong>IBM</strong> Support<br />

Center personnel to diagnose <strong>and</strong> correct the hardware<br />

problem.<br />

H<strong>CP</strong>9151E Processor nn {has stopped|operator is<br />

intervening.}<br />

Explanation: The unresponsive processor detection<br />

function has detected a processor that is unresponsive<br />

because of an OPERATOR INTERVENING or<br />

STOPPED condition.<br />

<strong>System</strong> Action: The message is repeated every ten<br />

seconds until the condition is corrected.<br />

User Response: None.<br />

Operator Response: Start the processor if the<br />

STOPPED condition is indicated. For OPERATOR<br />

INTERVENING, stop doing whatever is causing the<br />

intervention to be detected.<br />

H<strong>CP</strong>9152E Processor nn is being varied offline<br />

because it is not responsive.<br />

Explanation: The unresponsive processor detection<br />

function has determined that a processor is<br />

unresponsive.<br />

<strong>System</strong> Action: The unresponsive processor is varied<br />

offline.<br />

User Response: None.<br />

H<strong>CP</strong>9108E H<strong>CP</strong>9152E<br />

Chapter 3. <strong>System</strong> <strong>Messages</strong> 461