28.12.2012 Views

z/VM: System Messages and Codes Š CP - z/VM - IBM

z/VM: System Messages and Codes Š CP - z/VM - IBM

z/VM: System Messages and Codes Š CP - z/VM - IBM

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

H<strong>CP</strong>6152E H<strong>CP</strong>6157E<br />

ALEN translation exception<br />

(X'0029')<br />

ALE sequence exception<br />

(X'002A')<br />

ASTE validity exception<br />

(X'002B')<br />

ASTE sequence exception<br />

(X'002C')<br />

<strong>System</strong> Action: The comm<strong>and</strong> does not run; system<br />

operation continues.<br />

User Response: If the problem occurred during<br />

translation of an address, verify that the address is valid<br />

<strong>and</strong> try displaying that piece of storage directly. If<br />

unable to display the storage, contact a system<br />

programmer. If the problem occurred during translation<br />

of an address space specification to a segment table<br />

designation (STD), verify that your tables are set up<br />

correctly.<br />

H<strong>CP</strong>6152E The virtual machine whose TOD clock<br />

you want to change may not be in<br />

ESA/XC mode<br />

Explanation: The virtual machine whose TOD clock<br />

you want to change may not be in ESA/XC mode.<br />

<strong>System</strong> Action: The system continues to run, but the<br />

comm<strong>and</strong> the user entered does not process.<br />

User Response: If you wish to use this comm<strong>and</strong>,<br />

change the machine mode of the virtual machine whose<br />

TOD clock you want to change <strong>and</strong> retry the comm<strong>and</strong>.<br />

Operator Response: None.<br />

Programmer Response: None.<br />

H<strong>CP</strong>6153E Extended IEEE Floating-Point facilities<br />

are not installed.<br />

Explanation: The extended IEEE floating-point<br />

facilities are not installed on the processor where the<br />

system is running. Therefore, the requested oper<strong>and</strong> is<br />

not available.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues, but the<br />

comm<strong>and</strong> the user entered is not processed.<br />

User Response: Do not attempt to use the FPC<br />

oper<strong>and</strong> if your processor does not include IEEE<br />

Floating-Point facilities.<br />

H<strong>CP</strong>6154E Extended IEEE Floating-Point facilities<br />

are not active.<br />

Explanation: The extended IEEE Floating-Point<br />

facilities are installed on the processor where the<br />

system is running, but are not yet active for the virtual<br />

machine where the comm<strong>and</strong> was issued. Therefore,<br />

the requested oper<strong>and</strong> is not available.<br />

352 z/<strong>VM</strong>: <strong>System</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong> — <strong>CP</strong><br />

<strong>System</strong> Action: <strong>System</strong> operation continues, but the<br />

comm<strong>and</strong> the user entered is not processed.<br />

User Response: Enter this comm<strong>and</strong> again after the<br />

virtual machine has performed an IEEE floating-point<br />

operation <strong>and</strong> has thus been enabled to use IEEE<br />

Floating-Point facilities.<br />

H<strong>CP</strong>6155E Storage is not addressable because of<br />

an invalid PSW.<br />

Explanation: An invalid guest PSW prevented the<br />

logical address from being resolved.<br />

<strong>System</strong> Action: The comm<strong>and</strong> does not run; system<br />

operation continues.<br />

User Response: Validate the PSW <strong>and</strong> reenter the<br />

comm<strong>and</strong>.<br />

H<strong>CP</strong>6156E {ASIT asit|Address space identifier<br />

spaceid|Access register acc_reg|ALET<br />

alet} does not designate an address<br />

space to which you have the<br />

appropriate access.<br />

Explanation: The ASIT, SPACE ACCESS REGISTER,<br />

or ALET that you specified does not designate an<br />

address space, you don’t have the type of access you<br />

need to perform the current operation on the address<br />

space, or your access to the address space expired<br />

before you could use it.<br />

<strong>System</strong> Action: The system continues to run, but the<br />

comm<strong>and</strong> entered by the user is not processed.<br />

User Response: Verify that you are using a valid<br />

ASIT, SPACE, ACCESS REGISTER, or ALET, then<br />

request the appropriate access from the owner of the<br />

address space.<br />

H<strong>CP</strong>6157E Storage is no longer addressable<br />

because of an addressing-capability<br />

exception.<br />

Explanation: Your access to the address space<br />

expired while it was being used. The address space<br />

was originally specified in a DISPLAY/DUMP/STORE<br />

comm<strong>and</strong> using the ALET or AREG oper<strong>and</strong>, or by<br />

allowing a logical address space default to AREG.<br />

<strong>System</strong> Action: The system continues to run, but the<br />

comm<strong>and</strong> entered by the user is stopped while partially<br />

complete.<br />

User Response: Contact the owner of the address<br />

space to reestablish your access. Clean up the partially<br />

completed comm<strong>and</strong> if necessary.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!