<strong>VM</strong> Dump Tool (<strong>VM</strong>DT) <strong>Messages</strong><br />

HCQ001E Unrecognized oper<strong>and</strong> - oper<strong>and</strong><br />

Explanation: The indicated oper<strong>and</strong> is not valid or not<br />

recognized for the subcomm<strong>and</strong> with which it was<br />

issued.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> terminates.<br />

User Response: Enter the subcomm<strong>and</strong> again with a<br />

correct oper<strong>and</strong>.<br />

HCQ001W Unrecognized oper<strong>and</strong> ignored -<br />

oper<strong>and</strong><br />

Explanation: The indicated oper<strong>and</strong> is not valid or not<br />

recognized for the subcomm<strong>and</strong> with which it was<br />

issued.<br />

<strong>System</strong> Action: Processing continues.<br />

User Response: Enter the subcomm<strong>and</strong> again with a<br />

correct oper<strong>and</strong>.<br />

HCQ002E oper<strong>and</strong> missing<br />

Explanation: The indicated oper<strong>and</strong> is required for<br />

this subcomm<strong>and</strong> or macro, but was not found.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again with the required information.<br />

HCQ003E xxxxxxxx contains non-hex data<br />

Explanation: The indicated term must be a<br />

hexadecimal value, but contains a character other than<br />

0-9 <strong>and</strong> A-F.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again with hex data.<br />

HCQ004E Page xxxxxxxx not in dump<br />

Explanation: A page was requested either directly via<br />

subcomm<strong>and</strong> or macro or indirectly by processing within<br />

a subcomm<strong>and</strong> or macro <strong>and</strong> that page is not present in<br />

the dump. If ’virtual’ is displayed, the page is a<br />

host-virtual address. In all other cases, it is a <strong>CP</strong><br />

address.<br />

Form: The format of the page address when the high<br />

order word is zero is controlled by the SET HIWord<br />

comm<strong>and</strong>. Forms include:<br />

yyyyyyyy_yyyyyyyy<br />

0_yyyyyyyy<br />

_yyyyyyyy<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Request a page that exists in the<br />

dump.<br />

HCQ004W Page xxxxxxxx not in dump<br />

Explanation: A page was requested either directly via<br />

subcomm<strong>and</strong> or macro or indirectly by processing within<br />

a subcomm<strong>and</strong> or macro <strong>and</strong> that page is not present in<br />

the dump. If ’virtual’ is displayed, the page is a<br />

host-virtual address. In all other cases, it is a <strong>CP</strong><br />

address. This message is issued only when the SKIPS<br />

option is used on the LOCATE subcomm<strong>and</strong> indicating<br />

that the user wishes to be notified of all pages that were<br />

not found.<br />

Form: The format of the page address when the high<br />

order word is zero is controlled by the SET HIWord<br />

comm<strong>and</strong>. Forms include:<br />

yyyyyyyy_yyyyyyyy<br />

0_yyyyyyyy<br />

_yyyyyyyy<br />

<strong>System</strong> Action: Processing continues.<br />

HCQ001E HCQ006E<br />

User Response: Request a page that exists in the<br />

dump. To supress this message from LOCATE, do not<br />

use the SKIPS oper<strong>and</strong>.<br />

HCQ005E xxxxxxxx not yyyyyyyy aligned<br />

Explanation: The address for the xxxxxxxx term is<br />

required to be aligned to the boundary indicated by<br />

yyyyyyyy, but was not. Boundaries required can include<br />

the following:<br />

v half-word (ends in 0, 2, 4, 6, 8, A or C): instruction<br />

v full-word (ends in 0, 4, 8 or C): many control blocks<br />

v double-word (ends in 0 or 8): CCWs, some control<br />

blocks<br />

v quad-word (ends in 0): Frame Table Entry<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again using an address with the proper alignment.<br />

HCQ006E Extra parameter - parameter<br />

Explanation: The indicated parameter was found, but<br />

no more parameters are expected or allowed for this<br />

subcomm<strong>and</strong> or macro.<br />

<strong>System</strong> Action: The subcomm<strong>and</strong> or macro<br />

terminates.<br />

User Response: Enter the subcomm<strong>and</strong> or macro<br />

again using the correct parameters.<br />