28.12.2012 Views

z/VM: System Messages and Codes Š CP - z/VM - IBM

z/VM: System Messages and Codes Š CP - z/VM - IBM

z/VM: System Messages and Codes Š CP - z/VM - IBM

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

H<strong>CP</strong>6260I H<strong>CP</strong>6268E<br />

H<strong>CP</strong>6260I The Channel-Path-Measurement<br />

Facility encountered a recoverable<br />

error. <strong>VM</strong> is awaiting channel<br />

subsystem recovery.<br />

Explanation: The Channel-Path-Measurement Facility<br />

encountered a recoverable error.<br />

<strong>System</strong> Action: The Channel-Path-Measurement<br />

Facility is stopped. The facility will be restarted<br />

automatically when channel subsystem recovery is<br />

complete. In the interim, there will be no updates to the<br />

channel measurement data reported in Monitor records.<br />

Operator Response: None.<br />

H<strong>CP</strong>6261I The Channel-Path-Measurement<br />

Facility was successfully restarted.<br />

Explanation: The Channel-Path-Measurement Facility<br />

was successfully restarted after a recoverable error was<br />

detected.<br />

<strong>System</strong> Action: The Channel-Path-Measurement<br />

Facility is restarted.<br />

Operator Response: None.<br />

H<strong>CP</strong>6262E value is an invalid time limit for<br />

monitor {event|sample} CONFIG.<br />

Explanation: The value specified for CONFIG LIMIT<br />

on the MONITOR SAMPLE/EVENT comm<strong>and</strong> is invalid.<br />

This message is generated when one of the following is<br />

true:<br />

v A nonnumeric value was specified.<br />

v The CONFIG value is less than the minimum value or<br />

greater than the maximum value required as<br />

documented for the MONITOR CONFIG LIMIT<br />

comm<strong>and</strong>.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is rejected.<br />

User Response: Reenter the comm<strong>and</strong> with a valid<br />

value.<br />

H<strong>CP</strong>6265A Monitor writer connected to iucvserver<br />

action<br />

Explanation: Monitor writer has connected with the<br />

specified iucvserver. The writer will transfer any monitor<br />

data collected to the output file until it is stopped, using<br />

either the #<strong>CP</strong> EXTERNAL or MONWSTOP comm<strong>and</strong>.<br />

Note: The following message text appears only if no<br />

monitoring is active when the monitor writer<br />

connects to *MONITOR:<br />

action = START <strong>CP</strong> MONITOR.<br />

<strong>System</strong> Action: Monitor writer waits for<br />

communication from iucvserver to begin.<br />

Operator Response: If iucvserver is *MONITOR, <strong>and</strong><br />

362 z/<strong>VM</strong>: <strong>System</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong> — <strong>CP</strong><br />

the <strong>CP</strong> monitor is not started, start the <strong>CP</strong> monitor by<br />

entering the <strong>CP</strong> MONITOR START, <strong>CP</strong> MONITOR<br />

EVENT START, or <strong>CP</strong> MONITOR SAMPLE START<br />

comm<strong>and</strong>.<br />

If iucvserver is not *MONITOR, follow startup<br />

procedures for that application.<br />

H<strong>CP</strong>6266A End-of-tape encountered for vdev<br />

mount <strong>and</strong> ready a new writable tape<br />

Explanation: The end of the tape has been reached<br />

by monitor writer for the vdev given.<br />

<strong>System</strong> Action: The tape on the real device<br />

associated with vdev is rewound <strong>and</strong> unloaded. If only<br />

one virtual device was specified or defaulted on the<br />

MONWRITE comm<strong>and</strong>, monitor writer waits for the new<br />

tape to be mounted. If two virtual devices were specified<br />

on the MONWRITE comm<strong>and</strong>, writing continues on the<br />

other tape device.<br />

User Response: If the tape device has an automatic<br />

tape loading feature (for example: the cartridge stacker<br />

loader on the <strong>IBM</strong> 3480), no action is required unless<br />

the stacker is empty. If there is no automatic loading<br />

feature or the stacker is empty, contact the operator <strong>and</strong><br />

request that a new tape be mounted on the real device<br />

associated with the virtual device given in the message.<br />

Operator Response: If the tape device has an<br />

automatic tape-loading feature (for example, the<br />

cartridge stacker loader on the <strong>IBM</strong> 3480), no action is<br />

required unless the stacker is empty. If there is no<br />

automatic loading feature or the stacker is empty, mount<br />

a new tape on the real device associated with the given<br />

virtual device. Make sure the tape can be written to.<br />

H<strong>CP</strong>6267I Monitor writer connection to iucvserver<br />

ended<br />

Explanation: Monitor writer has ended<br />

communications with the given IUCV server.<br />

<strong>System</strong> Action: Monitor writer continues termination<br />

activity.<br />

User Response: None.<br />

H<strong>CP</strong>6268E Attempt to connect to monitor writer<br />

by application has been severed<br />

Explanation: An attempt was made by application to<br />

make an IUCV connection to the monitor writer function.<br />

The connect attempt has been severed.<br />

<strong>System</strong> Action: Monitor writer continues operation.<br />

User Response: Contact the system programmer.<br />

Determine who attempted the connection. The<br />

application variable is probably a user ID. The<br />

application issued an IUCV CONNECT (probably using<br />

the IUCV macro or the CMSIUCV macro) that specified<br />

MONWRITE as the target of that connection. Change

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!