H<strong>CP</strong>9020W H<strong>CP</strong>9025W<br />

H<strong>CP</strong>9020W SYSTEM LOAD FAILURE; PROGRAM<br />

CHECK<br />

Explanation: A program check occurred during the<br />

IPL process. The module code in the message identifier<br />

indicates the module executing when the program check<br />

occurred.<br />

<strong>System</strong> Action: The system enters a disabled wait<br />

state (wait-state code = 9020).<br />

If using the St<strong>and</strong>-Alone Program Loader, all registers<br />

will contain the values held at the time the wait state<br />

was entered.<br />

Operator Response: Take a st<strong>and</strong>-alone dump <strong>and</strong><br />

contact your system support personnel. Attempt a<br />

FORCE start. If that fails, attempt a COLD start. If the<br />

failure continues, contact your <strong>IBM</strong> Support Center<br />

personnel for assistance.<br />

H<strong>CP</strong>9021W SYSTEM LOAD FAILURE; MACHINE<br />

CHECK<br />

Explanation: A machine check occurred during the<br />

IPL process. The module code in the message identifier<br />

indicates the module executing when the machine<br />

check occurred.<br />

<strong>System</strong> Action: The system enters a disabled wait<br />

state (wait-state code = 9021).<br />

If using the St<strong>and</strong>-Alone Program Loader, all registers<br />

will contain the values held at the time the wait state<br />

was entered.<br />

Operator Response: IPL the system with a WARM<br />

start. If that fails, attempt a FORCE start. If that is<br />

unsuccessful, attempt a COLD start. If the failure<br />

continues, contact your <strong>IBM</strong> Support Center personnel<br />

for hardware support.<br />

H<strong>CP</strong>9022W SYSTEM LOAD FAILURE; FATAL I/O<br />

ERROR<br />

Explanation: An irrecoverable input/output error<br />

occurred on the system residence volume during the<br />

IPL process. The module code in the message identifier<br />

will show the module where the fatal I/O error occurred.<br />

<strong>System</strong> Action: The system enters a disabled wait<br />

state (wait-state code = 9022). The codes for this<br />

message are as follows:<br />

Code Explanation<br />

R0 Contains the address of the device in error<br />

R1–R3 Contains the extended status CSW in the<br />

interrupt response block<br />

R4–R11<br />

Contains up to 32 bytes of sense information<br />

R12 Base register if using the St<strong>and</strong>-Alone Program<br />

Loader<br />

456 z/<strong>VM</strong>: <strong>System</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong> — <strong>CP</strong><br />

R13 Work page address if using the St<strong>and</strong>-Alone<br />

Program Loader<br />

R14–R15<br />

Contains BBCCHHR if the device is a<br />

CKD/ECKD or zero if using the St<strong>and</strong>-Alone<br />

Program Loader<br />

R14 Contains the hexadecimal block number if the<br />

device is an FBA or zero if using the<br />

St<strong>and</strong>-Alone Program Loader.<br />

User Response: None.<br />

H<strong>CP</strong>9023W SYSTEM TERMINATION FAILURE;<br />

MULTIPLE INCIDENTS<br />

Explanation: Multiple system incidents have occurred<br />

on the same processor during the termination process.<br />

<strong>System</strong> Action: The system enters a wait state<br />

(wait-state code = 9023).<br />

Operator Response: Use the IPL NOCLEAR<br />

comm<strong>and</strong> to retry the checkpoint function. If the failure<br />

persists, contact your <strong>IBM</strong> support center.<br />

H<strong>CP</strong>9024W CONSOLE I/O ERROR<br />

Explanation: An irrecoverable I/O error occurred while<br />

the system was trying to write a message to the<br />

operator’s console. This is often caused on a<br />

second-level system by a console defined as something<br />

other than a 3270.<br />

<strong>System</strong> Action: The system enters a wait state<br />

(wait-state code = 9024). No message is displayed.<br />

Operator Response: Disable the console <strong>and</strong> attempt<br />

to IPL to get an alternate console. If you are running<br />

second level, make sure that your console is defined as<br />

a 3270.<br />

H<strong>CP</strong>9025W SYSTEM TERMINATION COMPLETE,<br />

ENTERING WAIT STATE<br />

Explanation: The system termination process has<br />

completed. The system will not restart for one of the<br />

following reasons:<br />

1. An error was detected in the error recovery<br />

hardware or software.<br />

2. A machine check shows damage to a storage page<br />

that the <strong>CP</strong> nucleus occupies.<br />

3. There is severe I/O subsystem damage.<br />

4. A hard abend occurred when dump conditions were<br />

set to NOIPL.<br />

5. The system has been successfully shut down <strong>and</strong><br />

has not been IPLed again. (This wait state will occur<br />

if a system restart is attempted after the shutdown<br />

comm<strong>and</strong> completed.)<br />

6. An attempt was made to IPL an alias Parallel<br />

Access Volume. An IIO002 abend will have occurred