H<strong>CP</strong>2887I H<strong>CP</strong>2893D<br />

H<strong>CP</strong>2887I XLINK RESET complete.<br />

Explanation: The XLINK RESET comm<strong>and</strong><br />

completed.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is processed, <strong>and</strong><br />

system operation continues.<br />

User Response: None.<br />

H<strong>CP</strong>2888I XLINK RESET ignored.<br />

Explanation: The XLINK RESET comm<strong>and</strong> was<br />

ignored because the response to message H<strong>CP</strong>2886D<br />

was NO (or not YES).<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not processed.<br />

User Response: None.<br />

H<strong>CP</strong>2889E XLINK RESET on your own system is<br />

not allowed.<br />

Explanation: You are trying to enter an XLINK RESET<br />

comm<strong>and</strong> for the system you are working on. Evidently,<br />

this system is still running. Since all link flags for a<br />

running system would be destroyed, which would result<br />

in loss of data on minidisks, the comm<strong>and</strong> is not<br />

executed.<br />

<strong>System</strong> Action: The comm<strong>and</strong> is not processed.<br />

User Response: Specify the correct system name.<br />

H<strong>CP</strong>2890E CSE I/O error, code cc, volume<br />

volserdevice rdev; LINK comm<strong>and</strong>s may<br />

fail.<br />

Explanation: This message is presented to the<br />

operator at IPL, or when a volume is attached to the<br />

system. The error occurred on volume volser, <strong>and</strong> the<br />

code cc identifies the kind of I/O error. The code, cc,<br />

has the following meaning:<br />

Code Meaning<br />

01 A write error occurred.<br />

02 The CSE track does not contain the expected<br />

CSE format, or the drive presented a real<br />

hardware I/O error.<br />

03 The CSE map record length on the CSE track<br />

is smaller than the start cylinder for this<br />

minidisk. This indicates that an incorrect CYL<br />

oper<strong>and</strong> was specified on a CSELVOL or<br />

CSELDEV macro.<br />

04 An I/O error occurred because of invalid<br />

channel comm<strong>and</strong> words.<br />

The error occurred when CSE tried to clear the map<br />

record of this system.<br />

Note: All LINK comm<strong>and</strong>s by virtual machines to<br />

minidisks on this volume will probably fail as well.<br />

326 z/<strong>VM</strong>: <strong>System</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong> — <strong>CP</strong><br />

<strong>System</strong> Action: The system continues to operate, but<br />

it denies all links to this volume while the error persists.<br />

User Response: If it is a hardware error, have the<br />

device repaired. If it is a write error, make sure that the<br />

WRITE INHIBIT switch is in the correct state. Make sure<br />

that the CSE system <strong>and</strong> volume tables in H<strong>CP</strong>SYS are<br />

correct. Also make sure that the CSE track is on volume<br />

volser. For code 2, if this system is an operating system<br />

before <strong>VM</strong>/ESA Version 1 Release 1.1 <strong>and</strong> this is an<br />

ECKD device, enter XLINK FORMAT for the volume<br />

from an earlier release of <strong>VM</strong>.<br />

H<strong>CP</strong>2891I CSE system table loaded at address<br />

raddr<br />

Explanation: The CSE system table is located at real<br />

storage address raddr.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

User Response: None.<br />

H<strong>CP</strong>2892I WARNING! XLINK RESET must be<br />

used with extreme caution. Improper<br />

use will cause loss of minidisk data.<br />

Explanation: An XLINK RESET comm<strong>and</strong> was<br />

entered. This comm<strong>and</strong> destroys all records of the links<br />

held by a particular system in the CSE complex. It must<br />

not be used unless the specified system is turned off, or<br />

has had its storage cleared <strong>and</strong> reset.<br />

<strong>System</strong> Action: This message is sent to the user who<br />

entered the comm<strong>and</strong> <strong>and</strong> to the system operator.<br />

User Response: Make sure the specified system in<br />

the XLINK RESET comm<strong>and</strong> is turned off, or has had<br />

its storage reset.<br />

H<strong>CP</strong>2893D CAUTION: Are you IPLing from a DASD<br />

device that is currently IPLed on<br />

another machine? Reply YES or NO:<br />

Explanation: The checkpoint cylinders on the IPLed<br />

DASD indicate that the system was not previously shut<br />

down on this machine. This can occur for the following<br />

reasons:<br />

v There are newly formatted checkpoint cylinders.<br />

<strong>System</strong> Action: The system continues IPL<br />

processing.<br />

User Response: Reply NO.<br />

v The system was previously IPLed on another<br />

machine <strong>and</strong> unsuccessfully shut down.<br />

<strong>System</strong> Action: The system continues IPL<br />

processing.<br />

User Response: Reply NO.<br />

v The system is currently IPLed on another machine.<br />

<strong>System</strong> Action: Message H<strong>CP</strong>2894W is displayed,<br />

<strong>and</strong> the system enters a disabled wait state (code<br />

009).