6 Operation<br />

Chapter 6<br />

Operation<br />

16<br />

6.13.4 Safety circuit when switching on the machine drive<br />

The driver's seat is equipped with a position encoder. Because of this, the machine<br />

drive can only be switched on with the yellow button (6) if the driver's seat is centered<br />

and turned forward and if you had an overview of the pickup. The rotatable seat<br />

6 status indicator (1) on the color terminal must display green (display range between<br />

-20%/0%/+20%). In addition, the pile pickup must be raised high enough so that the<br />

height indicator of the pile pickup (3) also shows green. To switch on the machine drive,<br />

only briefly press the yellow button (6).<br />

First, emit a short but clear horn signal to point out to all bystanders that you are<br />

starting the machine drive and that sufficient distance to the machine must be observed<br />

immediately.<br />

M4001911D<br />

3<br />

(4) Indicator for expiration of cooling-off period<br />

M4001910D<br />

3<br />

(4) Indicator for expiration of cooling-off period (5 seconds<br />

remaining)<br />

If the transport vehicles need to be exchanged rapidly, the machine drive can be<br />

switched on again without turning the driver's seat into the green zone. This is possible<br />

as long as the cooling off period has not expired. This period is counted down on the<br />

color terminal starting from the switch-off time of the machine drive.<br />

Recommendation for fuel-saving loading:<br />

Use the X-Y button (16) to select an engine speed speed between 1200 and 1300 rpm.<br />