13.05.2013 Views

Original Operating Manual - ROPA Fahrzeug

Original Operating Manual - ROPA Fahrzeug

Original Operating Manual - ROPA Fahrzeug

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Error code output<br />

When an error occurs, the display of the timer shows an error message.<br />

Error code output on the display of the timer<br />

379<br />

8 Troubleshooting<br />

F-- Heating system is locked<br />

Remedy: Switch on the independent heating system and, during the 90<br />

second error delayed switch-off, withdraw fuse F15 (in the central electrical<br />

system cabinet) and fuse F43 (in the radio console, at bottom) for a few<br />

seconds.<br />

F01 No start (after 2 attempts at starting)<br />

F02 Flame interruption<br />

F03 Undervoltage or overvoltage<br />

F04 Premature flame detection<br />

F05 Flame monitor interruption or flame monitor short circuit<br />

F06 Temperature sensor interruption or temperature sensor short circuit<br />

F07 Dosing pump interruption or dosing pump short circuit<br />

F08 Fan motor interruption or fan motor short circuit or fan motor faulty speed<br />

F09 Glow plug interruption or glow plug short circuit<br />

F10 Overheating<br />

F11 Circulating pump interruption or circulating pump short circuit<br />

Chapter 8<br />

Troubleshooting