13.05.2013 Views

Original Operating Manual - ROPA Fahrzeug

Original Operating Manual - ROPA Fahrzeug

Original Operating Manual - ROPA Fahrzeug

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

277<br />

7 Maintenance and Care<br />

Regularly check the hoses of the hydraulic system for aging and damage! Immediately<br />

exchange damaged or aged hoses. Only use hoses corresponding to the technical<br />

specifications of the original hose as replacements! For reasons of cost, we recommend<br />

that you order replacement hoses directly from <strong>ROPA</strong> since original <strong>ROPA</strong> hydraulic<br />

hoses are generally offered far more economically than competing products.<br />

1<br />

Note that a soiled cooler will achieve a clearly reduced cooling performance. This<br />

substantially reduces the loading capacity of the machine. If the hydraulic fluid is heated<br />

up too much, shut off the engine and try to determine the cause. Usually, the hydraulic<br />

fluid cooler (1) is soiled; possibly, the heating system for the hydraulic fluid tank has not<br />

been shut off.<br />

Warning! Risk of burns! Every radiator is heated during operation. Wear protective<br />

gloves! Before all work on the cooling systems, let the machine cool down sufficiently!<br />

7.3.1 Hydraulic fluid tank<br />

The tank for hydraulic fluid is located on the cab platform behind the handrail. In addition<br />

to the display on the color terminal, the oil level and oil temperature can be read off at<br />

the sight glass (3) on the front side of the hydraulic fluid tank. The hydraulic fluid level<br />

should always be in the area between the center of the sight glass and the upper edge<br />

of the sight glass. Always ensure that the fluid level in the hydraulic fluid tank is correct.<br />

During all work on the hydraulic system, ensure the utmost cleanliness!<br />

Note that different grades of hydraulic fluid may not be mixed.<br />

When using a vacuum pump, do not set a partial vacuum of more than 0.2 bar since this<br />

may otherwise cause damage to the hydraulic fluid tank.<br />

(1) Hydraulic fluid cooler<br />

Chapter 7<br />

Maintenance and Care

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!