8 Troubleshooting<br />

Chapter 8<br />

Troubleshooting<br />

8.19 Independent heating system (optional) – measures to be taken<br />

if errors occur<br />

When errors occur, the fuses and plug-in connections must be checked for perfect<br />

condition and tight fit.<br />

If these measures do not serve to remedy the error, then please contact a Webasto<br />

servicing outlet (www.webasto.com) stating the model of your independent heating<br />

system (Thermo 90 ST.25.D 24V).<br />

Heating is automatically switched off = shutdown due to malfunction<br />

Cause Remedy<br />

No combustion after starting and repeated Switch off heating device and switch it on<br />

starting.<br />

again. If again the heating system does not<br />

Flame goes out during operation.<br />

work, contact a Webasto servicing outlet.<br />

Voltage drop for longer than 20 seconds. Check fuses, plug-in connections and<br />

charging state of the battery.<br />

Heating device is overheated due to lacl/ Fill up coolant as stated in information from<br />

loss of coolant liquid.<br />

the vehicle manufacturer.<br />

Shutdown is caused by temperature limiter Let the device cool down, then depress<br />

(overheating).<br />

button (1) of the temperature limiter before<br />

restarting.<br />