7 Maintenance and Care<br />

Chapter 7<br />

Maintenance and Care<br />

7.3.1.2 Checking the intake strainers<br />

The intake strainers inside of the hydraulic fluid tank must be checked for soiling every<br />

two years before filling up the fresh hydraulic fluid by means of a visual inspection. If the<br />

intake strainers are soiled, clean them.<br />

– For this purpose, detach the metal cover (6) of the hydraulic fluid tank. Flush the<br />

intake strainers from inside to outside using sufficient cleaning agent .<br />

– Reinsert the intake strainers.<br />

Intake strainer on the inside of the hydraulic fluid tank<br />

– Place the gasket and the metal cover (6) on them.<br />

– Coat the bolts for fastening the metal cover (6) with sealing compound (<strong>ROPA</strong> Item<br />

No. 017026) before inserting them and tighten the bolts.<br />

6<br />

280<br />

5<br />

(5) Intake return filter<br />

(6) Metal cover