10.01.2015 Views

AT Command Reference Guide for EDGE Wireless ... - wless.ru

AT Command Reference Guide for EDGE Wireless ... - wless.ru

AT Command Reference Guide for EDGE Wireless ... - wless.ru

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter 11 – GPRS <strong>Command</strong>s<br />

<br />

This parameter indicates the guaranteed number of kbits/s delivered to UMTS (up-link traffic) at a SAP (provided<br />

that there is data to deliver). As an example a bitrate of 32kbit/s would be specified as 32<br />

(e.g., <strong>AT</strong>+CGEQREQ=...,32,...).<br />

0 subscribed value. Default<br />

1...63<br />

64...128 (value needs to be divisible by 8 without remainder)<br />

<br />

This parameter indicates the guaranteed number of kbits/s delivered by UMTS (down-link traffic) at a SAP<br />

(provided that there is data to deliver). As an example a bitrate of 32kbit/s would be specified as 32<br />

(e.g., <strong>AT</strong>+CGEQREQ=...,32,...).<br />

0 subscribed value. Default<br />

1...63<br />

64...256 (value needs to be divisible by 8 without remainder)<br />

<br />

This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.<br />

0 no<br />

1 yes<br />

2 subscribed value. Default<br />

<br />

This parameter indicates the maximum allowed SDU size in octets.<br />

0 subscribed value. Default<br />

10...1520 (value needs to be divisible by 10 without remainder)<br />

1502<br />

<br />

This parameter indicates the target value <strong>for</strong> the fraction of SDUs lost or detected as erroneous. SDU error ratio<br />

is defined only <strong>for</strong> con<strong>for</strong>ming traffic. The value is specified as “mEe”. As an example a target SDU error ratio<br />

of 5*10-3 would be specified as “5E3” (e.g., <strong>AT</strong>+CGEQREQ=...,”5E3”,...).<br />

“0E0“<br />

subscribed value. Default<br />

“1E2“<br />

“7E3“<br />

“1E3“<br />

“1E4“<br />

“1E5“<br />

“1E6“<br />

“1E1“<br />

<br />

This parameter indicates the target value <strong>for</strong> the undetected bit error ratio in the delivered SDUs. If no error<br />

detection is requested, Residual bit error ratio indicates the bit error ratio in the delivered SDUs. The value is<br />

specified as “mEe”. As an example a target residual bit error ratio of 5*10-3 would be specified as “5E3”<br />

(e.g., <strong>AT</strong>+CGEQREQ=...,”5E3”,...).<br />

“0E0“<br />

subscribed value. Default<br />

“5E2“<br />

“1E2“<br />

“5E3“<br />

“4E3“<br />

“1E3“<br />

“1E4“<br />

“1E5“<br />

“1E6“<br />

“6E8“<br />

<br />

This parameter indicates whether SDUs detected as erroneous shall be delivered or not.<br />

0 no<br />

1 yes<br />

2 no detect<br />

3 subscribed value. Default<br />

<br />

This parameter indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the<br />

other SAP, in milliseconds.<br />

[0] subscribed value. Default<br />

10...150 (value needs to be divisible by 10 without remainder)<br />

200...950 (value needs to be divisible by 50 without remainder)<br />

1000...4000 (value needs to be divisible by 100 without remainder)<br />

Multi-Tech Systems, Inc. <strong>AT</strong> <strong>Command</strong>s <strong>for</strong> <strong>EDGE</strong> Modems (S000371B) 153