Chapter 13 – Short Message Service (SMS) <strong>Command</strong>s<br />

13.26 <strong>AT</strong>^SSCONF SMS <strong>Command</strong> Configuration<br />

Description:<br />

<strong>AT</strong>^SSCONF controls details of some SMS releated commands. Please note that<br />

<strong>AT</strong>^SSCONF settings are stored volatile; i.e., after restart or reset the default values will<br />

be restored.<br />

Test <strong>Command</strong> Syntax: <strong>AT</strong>^SSCONF=<br />

Response:<br />

^SSCONF:list of supported s<br />

OK<br />

Read <strong>Command</strong> Syntax: <strong>AT</strong>^SSCONF<br />

Response:<br />

^SSCONF:<br />

OK<br />

Write <strong>Command</strong> Syntax: <strong>AT</strong>^SSCONF=<br />

Response:<br />

OK<br />

Parameter Description:<br />

<br />

Display recipient address<br />

0 The Multi-Tech wireless modem does not display and . These parameters are used<br />

with the result codes of <strong>AT</strong>+CMGL, <strong>AT</strong>^SMGL, <strong>AT</strong>+CMGR, <strong>AT</strong>^SMGR and the URC “+CDS”.<br />

Default.<br />

1 Multi-Tech wireless modem displays and .<br />

13.27 <strong>AT</strong>^SSDA Set SMS Display Availability<br />

Description: This command allows to notify the Multi-Tech wireless modem of its controlling application’s<br />

capability to immediately display incoming SMS on a display.<br />

If the application is able to display incoming short messages, a class 0 message shall be<br />

displayed immediately.<br />

However, if it does not, class 0 messages shall be treated as if no message class is determined<br />

(GSM 03.38[17]).<br />

The effect of this command if =1 is to determine the behavior of parameter of<br />

<strong>AT</strong>+CNMI:<br />

If multiplex mode is enabled (<strong>AT</strong>+CMUX) and =1 with =1 is set on any logical<br />

channel, all other channels have to use =0.<br />

Test <strong>Command</strong> Syntax: <strong>AT</strong>^SSDA=<br />

Response:<br />

^SSDA:list of supported s<br />

OK<br />

Read <strong>Command</strong> Syntax: <strong>AT</strong>^SSDA<br />

The read command returns ME’s current capability setting.<br />

Response:<br />

^SSDA:<br />

OK<br />

Write <strong>Command</strong> Syntax: <strong>AT</strong>^SSDA=<br />

Response:<br />

OK<br />

Parameter Description:<br />

<br />

Display Availability<br />

0 Application is not able to display incoming short message. Default.<br />

1 Application is able to display incoming short message.<br />

Note:<br />

If the ME operates on different instances (MUX channels 1, 2, 3 or ASC0) avoid different settings<br />

<strong>for</strong> routing and indicating short messages. For example, if messages shall be routed directly to<br />

one instance of the TE (set with <strong>AT</strong>+CNMI, <strong>AT</strong>^SSDA), it is not possible to activate the<br />

presentation of URCs with <strong>AT</strong>+CMER or <strong>AT</strong>+CNMI on another instance. Any attempt to activate<br />

settings that conflict with existing settings on another interface, will result in CME ERROR, or<br />

accordingly CMS ERROR.<br />

Multi-Tech Systems, Inc. <strong>AT</strong> <strong>Command</strong>s <strong>for</strong> <strong>EDGE</strong> Modems (S000371B) 191

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!