Chapter 4 – Serial Interface Control <strong>Command</strong>s<br />

Parameter Descriptions:<br />

<br />

0 Disables reporting of local port rate<br />

1 Enables reporting of local port rate<br />

<br />

Port rate setting upon connection setup (bps)<br />

0 Autobauding (see Section 4.9.1, Autobauding).<br />

300<br />

600<br />

1200<br />

2400<br />

4800<br />

9600<br />

14400<br />

19200<br />

28800<br />

38400<br />

57600<br />

115200<br />

230400<br />

460800<br />

4.9 <strong>AT</strong>+IPR Set Fixed Local Rate<br />

Description:<br />

Test <strong>Command</strong> Syntax: <strong>AT</strong>+IPR=<br />

Response:<br />

Read <strong>Command</strong> Syntax: <strong>AT</strong>+IPR<br />

Response:<br />

The command <strong>AT</strong>+IPR can be used to set or query the TE-TA interface bit rate.<br />

The test command returns the values of the supported automatically detectable bit rates and the<br />

values of the supported fixed bit rates.<br />

The read command returns the current bit rate of the interface.<br />

The write command specifies the bit rate to be used <strong>for</strong> the interface. When you set a fixed-rate,<br />

make sure that both TE (DTE) and TA (DCE) are configured to the same rate. When you select<br />

autobauding, the TA will automatically recognize the bit rate currently used by the TE.<br />

The setting is stored in the non-volatile memory and will be used whenever the engine is<br />

powered up again. However, in case of autobaud mode (<strong>AT</strong>+IPR=0) the detected TA bit rate will<br />

not be saved and, there<strong>for</strong>e, needs to be resynchronized after restarting the GSM engine (see<br />

Section 4.91, Autobauding).<br />

+IPR: <br />

OK<br />

Write <strong>Command</strong> Syntax: <strong>AT</strong>+IPR=<br />

Response:<br />

+IPR: (list of supported auto-detectable s) , (list of supported fixed-only s)<br />

OK<br />

OK<br />

ERROR<br />

+CME ERROR<br />

Parameter DescriptionsD<br />

<br />

bit rate per second (bps)<br />

0 Default. Activates autobauding. See Section 4.91, Autobauding <strong>for</strong> further details.<br />

300<br />

600<br />

1200<br />

2400<br />

4800<br />

9600<br />

14400<br />

19200<br />

28800<br />

38400<br />

57600<br />

115200<br />

230400<br />

460800<br />

Notes:<br />

• Factory default is autobauding enabled (<strong>AT</strong>+IPR=0). It will not be restored with <strong>AT</strong>&F.<br />