AT Command Reference Guide for EDGE Wireless ... - wless.ru
AT Command Reference Guide for EDGE Wireless ... - wless.ru
AT Command Reference Guide for EDGE Wireless ... - wless.ru
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Chapter 4 – Serial Interface Control <strong>Command</strong>s<br />
Parameter Descriptions:<br />
<br />
0 Disables reporting of local port rate<br />
1 Enables reporting of local port rate<br />
<br />
Port rate setting upon connection setup (bps)<br />
0 Autobauding (see Section 4.9.1, Autobauding).<br />
300<br />
600<br />
1200<br />
2400<br />
4800<br />
9600<br />
14400<br />
19200<br />
28800<br />
38400<br />
57600<br />
115200<br />
230400<br />
460800<br />
4.9 <strong>AT</strong>+IPR Set Fixed Local Rate<br />
Description:<br />
Test <strong>Command</strong> Syntax: <strong>AT</strong>+IPR=<br />
Response:<br />
Read <strong>Command</strong> Syntax: <strong>AT</strong>+IPR<br />
Response:<br />
The command <strong>AT</strong>+IPR can be used to set or query the TE-TA interface bit rate.<br />
The test command returns the values of the supported automatically detectable bit rates and the<br />
values of the supported fixed bit rates.<br />
The read command returns the current bit rate of the interface.<br />
The write command specifies the bit rate to be used <strong>for</strong> the interface. When you set a fixed-rate,<br />
make sure that both TE (DTE) and TA (DCE) are configured to the same rate. When you select<br />
autobauding, the TA will automatically recognize the bit rate currently used by the TE.<br />
The setting is stored in the non-volatile memory and will be used whenever the engine is<br />
powered up again. However, in case of autobaud mode (<strong>AT</strong>+IPR=0) the detected TA bit rate will<br />
not be saved and, there<strong>for</strong>e, needs to be resynchronized after restarting the GSM engine (see<br />
Section 4.91, Autobauding).<br />
+IPR: <br />
OK<br />
Write <strong>Command</strong> Syntax: <strong>AT</strong>+IPR=<br />
Response:<br />
+IPR: (list of supported auto-detectable s) , (list of supported fixed-only s)<br />
OK<br />
OK<br />
ERROR<br />
+CME ERROR<br />
Parameter DescriptionsD<br />
<br />
bit rate per second (bps)<br />
0 Default. Activates autobauding. See Section 4.91, Autobauding <strong>for</strong> further details.<br />
300<br />
600<br />
1200<br />
2400<br />
4800<br />
9600<br />
14400<br />
19200<br />
28800<br />
38400<br />
57600<br />
115200<br />
230400<br />
460800<br />
Notes:<br />
• Factory default is autobauding enabled (<strong>AT</strong>+IPR=0). It will not be restored with <strong>AT</strong>&F.<br />
Multi-Tech Systems, Inc. <strong>AT</strong> <strong>Command</strong>s <strong>for</strong> <strong>EDGE</strong> Modems (S000371B) 54