7.13 <strong>AT</strong>S6 Set Pause be<strong>for</strong>e Blind Dialing<br />

Description:<br />

No effect <strong>for</strong> GSM.<br />

Read <strong>Command</strong> Syntas: <strong>AT</strong>S6<br />

Response(s):<br />

<br />

OK<br />

Write <strong>Command</strong> Syntas: <strong>AT</strong>S6=<br />

Response(s):<br />

OK<br />

ERROR<br />

Parameter Description:<br />

<br />

000 – 255 Default is 000<br />

Chapter 7 – Call-Related <strong>Command</strong>s<br />

7.14 <strong>AT</strong>S7 Set Number of Seconds to Wait <strong>for</strong><br />

Connection Completion<br />

Description:<br />

<strong>AT</strong>S7 specifies the number of seconds the TA will wait <strong>for</strong> the completion of the call setup<br />

when answering or originating a data call. Also referred to as “no answer timeout”. To put<br />

it plainly, this is the time to wait <strong>for</strong> the carrier signal. If no carrier signal is received within<br />

the specified time, the TA hangs up.<br />

Read <strong>Command</strong> Syntax: <strong>AT</strong>S7<br />

Response(s):<br />

<br />

OK<br />

Write <strong>Command</strong> Syntax: <strong>AT</strong>S7=<br />

Response(s):<br />

OK<br />

ERROR<br />

Parameter Description:<br />

<br />

Number of seconds to wait <strong>for</strong> connection completion 000...060 (Default is 060)<br />

Notes:<br />

• <strong>Command</strong> <strong>AT</strong>S7 is applicable only to data calls.<br />

• Values greater than 60 (maximum 255) cause no error, but will be restored to the maximum value of 60.<br />

• The correlation between <strong>AT</strong>S7 and <strong>AT</strong>S0 is important. If the called party has specified a high value <strong>for</strong><br />

<strong>AT</strong>S0=, call setup may fail.<br />

Example: Call setup may fail if <strong>AT</strong>S7=30 and <strong>AT</strong>S0=20.<br />

7.15 <strong>AT</strong>S8 Set Number of Seconds to Wait <strong>for</strong><br />

Comma Dialing Modifier<br />

Description:<br />

No effect <strong>for</strong> GSM. This command specifies the amount of time, in seconds, that the DCE<br />

shall pause, during signaling of call addressing in<strong>for</strong>mation to the network (dialing), when<br />

a “,” (comma) dial modifier is encountered in a dial string.<br />

Read <strong>Command</strong> Syntax: <strong>AT</strong>S8<br />

Response:<br />

<br />

OK<br />

Write <strong>Command</strong> Syntax: <strong>AT</strong>S8=<br />

Response:<br />

OK<br />

ERROR<br />

Parameter Description:<br />

<br />

0 DCE does not pause when “,” encountered in dial string. Default.<br />

1...255 Number of seconds to pause<br />

Multi-Tech Systems, Inc. <strong>AT</strong> <strong>Command</strong>s <strong>for</strong> <strong>EDGE</strong> Modems (S000371B) 82

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!