Chapter 7 – Call-Related <strong>Command</strong>s<br />

7.26 <strong>AT</strong>^SCNI List Call Number In<strong>for</strong>mation<br />

Description:<br />

TA returns a list of current calls of ME.<br />

Test <strong>Command</strong> Syntax: <strong>AT</strong>^SCNI=<br />

Response:<br />

OK<br />

Exec <strong>Command</strong> Syntax: <strong>AT</strong>^SCNI<br />

Response:<br />

^SCNI: 1[,[,,]]<br />

^SCNI: 2[,[,,]]<br />

[...]<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

Parameter Descriptions:<br />

<br />

Call identification number; this number can be used in <strong>AT</strong>+CHLD command operations.<br />

1...7<br />

<br />

Call status of respective call number (first parameter)<br />

0 call hold<br />

1 call in progress<br />

2 waiting call<br />

<br />

string type phone number in <strong>for</strong>mat specified by <br />

<br />

type of address octet in integer <strong>for</strong>mat; 145 when dialing string includes international access code character “+”;<br />

otherwise 129<br />

Note: See also <strong>AT</strong>+CLCC<br />

7.27 <strong>AT</strong>^SLCD Display Last Call Duration<br />

Description:<br />

TA returns last call duration or current call duration.<br />

Test <strong>Command</strong> Syntax: <strong>AT</strong>^SLCD=<br />

Response:<br />

OK<br />

ERROR<br />

+CME ERROR<br />

Exec <strong>Command</strong> Syntax: <strong>AT</strong>^SLCD<br />

Response:<br />

^SLCD: <br />

OK<br />

ERROR<br />

+CME ERROR<br />

Parameter Description:<br />

<br />

Format is “hh:mm:ss”, where characters indicate hours, minutes, seconds; e.g., 22:10:00 “22:10:00”<br />

Max value is 9999:59:59<br />

Note: The proper working of that command is network dependent.<br />

7.28 <strong>AT</strong>^STCD Display Total Call Duration<br />

Description:<br />

TA returns total call duration (accumulated duration of all calls).<br />

Test <strong>Command</strong> Syntax: <strong>AT</strong>^STCD=<br />

Response:<br />

OK<br />

ERROR<br />

+CME ERROR<br />

Exec <strong>Command</strong> Syntax: <strong>AT</strong>^STCD<br />

Response:<br />

^STCD: <br />

OK<br />

ERROR<br />

+CME ERROR<br />

Parameter Description:<br />

<br />

Format is “hh:mm:ss”, where characters indicate hours, minutes, seconds; e.g., 22:10:00 “22:10:00”<br />

Max value is 9999:59:59<br />

Notes:<br />

• The Total Call Duration will not be reset by power off or other means.<br />

• The proper working of that command is network dependant and only <strong>for</strong> MO calls.<br />

Multi-Tech Systems, Inc. <strong>AT</strong> <strong>Command</strong>s <strong>for</strong> <strong>EDGE</strong> Modems (S000371B) 91