Chapter 2 – Configuration <strong>Command</strong>s<br />

The parameter determines the maximum range of the bands allowed. The value may be one of the<br />

single bands listed below or all valid combinations from the values 1, 2, 4 and 8. Thus, the value range of<br />

is “1”..”15”. To select or deselect a band calculate the sum of the values of all desired bands and enter<br />

the resulting value. For example, <strong>for</strong> 1800 MHz (2) and 850 MHz (8) please enter the value (10).<br />

Parameter is global <strong>for</strong> the ME, non-volatile and will not be reset by <strong>AT</strong>&F.<br />

“1“ GSM 900 MHz<br />

“2“ GSM 1800 MHz<br />

“4“ GSM 1900 MHz<br />

“8“ GSM 850 MHz<br />

“3“ GSM 900 MHz + GSM 1800 MHz<br />

“5“ GSM 900 MHz + GSM 1900 MHz<br />

“10“ GSM 850 MHz + GSM 1800 MHz<br />

“12“ GSM 850 MHz + GSM 1900 MHz<br />

“15“ all bands<br />

Preferred Radio Band(s)<br />

The parameter may be one of the single bands or one of the four dual-band combinations listed below.<br />

All preferred bands must be contained in the range of allowed bands (see ), invalid combinationsare not<br />

accepted. To give priority to a certain single band or band combination and suppress all others simply select the<br />

same value both <strong>for</strong> and .<br />

primarily serves to trigger the network search; i.e., it is only used one time <strong>for</strong> searching and selecting a<br />

network. As the currently used band depends on the availability of the allowed networks, the value indicated by<br />

may be different from . Also, the next time a network search is necessary (<strong>for</strong> example, after restart)<br />

the ME will first try to reselect the network last used, which may be different from the value of last given.<br />

There<strong>for</strong>e, the setting of will not be saved.<br />

The value range of is “1...12”, but only the band(s) selections listed below are allowed. Trying to set an<br />

unsupported value will be denied with “ERROR”. To select or deselect a band calculate the sum of the values of<br />

all desired bands and enter the resulting value. For example, <strong>for</strong> GSM 1800 MHz (2) and GSM 850 MHz (8)<br />

please enter the value (10).<br />

“1“ GSM 900 MHz<br />

“2“ GSM 1800 MHz<br />

“4“ GSM 1900 MHz<br />

“8“ GSM 850 MHz<br />

“3“ GSM 900 MHz + GSM 1800 MHz<br />

“5“ GSM 900 MHz + GSM 1900 MHz<br />

“10“ GSM 850 MHz + GSM 1800 MHz<br />

“12“ GSM 850 MHz + GSM 1900 MHz<br />

Currently Selected Radio Band(s)<br />

The band(s) indicated with are all allowed bands found at a location area. This means, if prompted to<br />

select a network the ME will search <strong>for</strong> these networks only. The value can be either a single band or a dualband<br />

combination.<br />

is only a response parameter returned either after sending the read command <strong>AT</strong>^SCFG or writing<br />

<strong>AT</strong>^SCFG=”Radio/Band”.<br />

In addition to and to allow the subscriber to be notified whenever the selected band changes it is<br />

recommended to activate the “+CIEV” (see Section 3.3, <strong>AT</strong>^SIND).<br />

“1“ GSM 900 MHz<br />

“2“ GSM 1800 MHz<br />

“4“ GSM 1900 MHz<br />

“8“ GSM 850 MHz<br />

“3“ GSM 900 MHz + GSM 1800 MHz<br />

“5“ GSM 900 MHz + GSM 1900 MHz<br />

“10“ GSM 850 MHz + GSM 1800 MHz<br />

“12“ GSM 850 MHz + GSM 1900 MHz<br />

Radio Output Power Reduction<br />

According to 3GPP Rel99, output power reduction <strong>for</strong> multiple TX slots is a mandatory feature. The amount of<br />

power reduction is configurable up to 3.0dB <strong>for</strong> 2TX, 4.8dB <strong>for</strong> 3Tx to 6dB <strong>for</strong> 4TX. To optimize heat dissipation,<br />

power consumption, and SAR values, it is recommended to use full power reduction (value “3”).<br />

The parameter is global <strong>for</strong> all interfaces, non volatile, and will not be reset by <strong>AT</strong>&F.<br />

“1“ Medium Reduction at GMSK and 8PSK (0dB <strong>for</strong> 1TX and 2TX, 1.8dB <strong>for</strong> 3TX and 3dB<br />

reduction 4TX<br />

“2“ Medium Reduction at GMSK (1TX 0dB, 2TX 3dB, 3TX 4.8dB and 4TX 6dB reduction) and<br />

Full Power at 8PSK (1TX and 2TX 0dB reduction)<br />

“3“ Maximal Reduction at GMSK and 8PSK (1TX 0dB, 2TX 3dB, 3TX 4.8dB and 4TX 6dB<br />

reduction). Default.<br />

Multi-Tech Systems, Inc. <strong>AT</strong> <strong>Command</strong>s <strong>for</strong> <strong>EDGE</strong> Modems (S000371B) 33