Chapter 7 – Call-Related <strong>Command</strong>s<br />

7.19 <strong>AT</strong>+CBST Select Bearer Service Type<br />

Description:<br />

Test <strong>Command</strong> Syntax: <strong>AT</strong>+CBST=<br />

Response(s):<br />

Read <strong>Command</strong> Syntax: <strong>AT</strong>+CBST<br />

Response(s):<br />

The <strong>AT</strong>+CBST write command selects the bearer service , the data rate <br />

and the connection element to be used when data calls are originated. The settings<br />

also apply to mobile terminated data calls, especially when single numbering scheme calls<br />

or calls from analog devices are received (see <strong>AT</strong>+CSNS). See GSM 02.02[1] <strong>for</strong> a list of<br />

allowed combinations of subparameters.<br />

+CBST: (list of supporteds), (list of supporteds), (list of supporteds)<br />

OK<br />

+CBST: , , <br />

OK<br />

Write <strong>Command</strong> Syntax: <strong>AT</strong>+CBST=[, [, ]]<br />

Response(s):<br />

OK, ERROR<br />

Parameter Descriptions:<br />

<br />

0 Autobauding<br />

1 300 bps (V.21)<br />

2 1200 bps (V.22)<br />

4 2400 bps (V.22bis)<br />

6 4800 bps (V.32)<br />

7 9600 bps (V.32) Default<br />

14 14400 bps (V.34)<br />

65 300 bps (V.110)<br />

66 1200 bps (v.110)<br />

68 2400 bps (V.110)<br />

70 4800 bps (V.110)<br />

71 9600 bps (V.110)<br />

75 14400 bps (V.110)<br />

<br />

0 Asynchronous modem. Default<br />

<br />

Transparent mode is not supported.<br />

1 Non-transparent. Default<br />

7.20 <strong>AT</strong>+CRLP Select Radio Link Protocol<br />

Parameters <strong>for</strong> Originated Non-Transparent Data<br />

Calls<br />

Description:<br />

Test <strong>Command</strong> Syntax: <strong>AT</strong>+CRLP=<br />

Response(s):<br />

Read <strong>Command</strong> Syntax: <strong>AT</strong>+CRLP<br />

Response(s):<br />

The <strong>AT</strong>+CRLP write command sets radio link protocol (RLP) parameters used when nontransparent<br />

data calls are originated. The read command returns the current settings <strong>for</strong><br />

the supported RLP version 0.<br />

+CRLP: (list of supporteds), (list of supporteds), (list of supporteds), (list<br />

of supporteds)<br />

OK<br />

+CRLP: , , , <br />

OK<br />

Write <strong>Command</strong> Syntax: <strong>AT</strong>+CRLP=[[, [, [, ]]]]<br />

Response(s):<br />

Parameter Descriptions:<br />

<br />

Interworking window size (IWF to MS)<br />

0...61 Default is 61<br />

<br />

Mobile window size (MS to IWF)<br />

0...61 Default is 61<br />

<br />

Acknowledgement timer (T1 in 10 ms units)<br />

48 - 255 Default is 78<br />

<br />

Re-transmission attempts N2<br />

1...255 Default is 6<br />

OK, ERROR, +CME ERROR: <br />