Main<br />

remote<br />

controller<br />

P22<br />

P26<br />

P29<br />

Check code<br />

Outdoor 7-segment display<br />

Check<br />

code<br />

P22<br />

P26<br />

P29<br />

Sub-code<br />

0: IGBT circuit<br />

1: Position<br />

detection circuit<br />

error<br />

3: Motor lockup<br />

error<br />

4: Motor current<br />

detection<br />

C: TH sensor<br />

temperature<br />

error<br />

D: TH sensor<br />

error<br />

E: Inverter DC<br />

voltage error<br />

(outdoor fan)<br />

Note:<br />

Although<br />

letters 0 to F<br />

appear at<br />

locations<br />

indicated by<br />

“”, please<br />

ignore them.<br />

01: Compressor<br />

1 side<br />

02: Compressor<br />

2 side<br />

03: Compressor<br />

3 side<br />

01: Compressor<br />

1 side<br />

02: Compressor<br />

2 side<br />

03: Compressor<br />

3 side<br />

AI-NET central<br />

control<br />

remote<br />

controller<br />

1A<br />

14<br />

16<br />

P31 – – 47<br />

Location<br />

of<br />

detection<br />

IPDU<br />

IPDU<br />

IPDU<br />

Indoor<br />

unit<br />

Description<br />

Outdoor fan<br />

IPDU error<br />

G-TR shortcircuit<br />

protection<br />

error<br />

Compressor<br />

position<br />

detection circuit<br />

error<br />

Other indoor<br />

error<br />

(group follower<br />

unit error)<br />

System status<br />

Error detection<br />

condition(s)<br />

All stop (Sub code: 0)<br />

Fan IPDU over current<br />

protection circuit<br />

Flow of current equal to or<br />

greater than the specified<br />

value is detected during<br />

startup of the fan.<br />

All stop (Sub code: 1)<br />

Fan IPDU position detection<br />

circuit<br />

Position detection is not<br />

going on normally.<br />

All stop (Sub code: 3)<br />

Gusty wind, an obstruction,<br />

or another external factor<br />

Speed estimation is not<br />

going on normally.<br />

All stop (Sub code: 4)<br />

Fan IPDU over current<br />

protection circuit<br />

Flow of current equal to or<br />

greater than the specified<br />

value is detected during<br />

operation of the fan.<br />

All stop<br />

All stop<br />

All stop<br />

All stop<br />

All stop<br />

Stop of<br />

corresponding<br />

unit<br />

(Sub code: C)<br />

Higher temperature than the<br />

specified value is detected<br />

during operation of the fan.<br />

(Sub code: D)<br />

The resistance value of the<br />

sensor is infinite or zero<br />

(open or short circuit).<br />

(Sub code: E)<br />

Fan IPDU DC voltage<br />

protection circuit<br />

The DC voltage higher or<br />

lower than the specified<br />

value is detected.<br />

Overcurrent is momentarily<br />

detected during startup of<br />

compressor.<br />

Position detection is not<br />

going on normally.<br />

There is error in other indoor<br />

unit in group, resulting in<br />

detection of E07/L07/L03/<br />

L08.<br />

Check items (locations)<br />

• Check fan motor.<br />

• Check for defect in fan<br />

IPDU P.C. board.<br />

• Check fan motor.<br />

• Check connection of fan<br />

motor connector.<br />

• Check for defect in fan<br />

IPDU P.C. board.<br />

• Check fan motor.<br />

• Check for defect in fan<br />

IPDU P.C. board.<br />

• Check fan motor.<br />

• Check connection of fan<br />

motor connector.<br />

• Check for defect in fan<br />

IPDU P.C. board.<br />

• Check fan motor.<br />

• Check for defect in fan<br />

IPDU P.C. board.<br />

• Check for defect in fan<br />

IPDU P.C. board.<br />

• Check power voltage of<br />

the main power supply.<br />

• Check for defect in fan<br />

IPDU P.C. board.<br />

• Check connection of fan<br />

IPDU P.C. board.<br />

• Check connector<br />

connection and wiring on<br />

A3-IPDU P.C. board.<br />

• Check for defect in<br />

compressor (layer shortcircuit).<br />

• Check for defect in<br />

outdoor P.C. board (A3-<br />

IPDU).<br />

• Check wiring and<br />

connector connection.<br />

• Check for compressor<br />

layer short-circuit.<br />

• Check for defect in A3-<br />

IPDU P.C. board.<br />

• Check indoor P.C. board.<br />

191