16.04.2015 Views

MULTI TYPE

MULTI TYPE

MULTI TYPE

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Central<br />

control<br />

remote<br />

controller<br />

(optional)<br />

(In case of<br />

AI-NETWORK)<br />

X<br />

Y<br />

Indoor unit<br />

#1<br />

Network adaptor (optional)<br />

Network<br />

adaptor P.C.<br />

board<br />

(MCC-1401)<br />

Remote controller<br />

communication<br />

circuit<br />

AI-NET<br />

communication<br />

circuit<br />

DC5V<br />

Power supply circuit<br />

CPU<br />

H8/3687<br />

Switch setting<br />

Transformer<br />

PMV<br />

* 1-way Type only<br />

Louver<br />

motor<br />

*Not applicable to<br />

concealed duct high<br />

static pressure type<br />

Drain<br />

pump<br />

Indoor<br />

fan<br />

motor<br />

Main (sub) center remote controller (up to 2 units)<br />

Weekly timer<br />

Display<br />

LCD<br />

Display<br />

LED<br />

EEPROM<br />

CPU<br />

Function setting<br />

Key switch<br />

Display<br />

LCD<br />

LCD<br />

driver<br />

CPU<br />

Function setting<br />

Key switch<br />

Remote controller<br />

communication circuit<br />

DC5V<br />

Power<br />

supply<br />

circuit<br />

CN2 CN1<br />

*3<br />

Power<br />

supply<br />

circuit<br />

DC5V<br />

Rechargeable<br />

battery<br />

Indoor control P.C. board (MCC-1403)<br />

DC20V<br />

DC12V<br />

DC5V<br />

Power supply circuit<br />

A B #2 A B #3 A B<br />

EEPROM<br />

*Not applicable to 1-way<br />

air discharge cassette<br />

type (compact)<br />

Driver<br />

Fan motor<br />

relay circuit<br />

External<br />

output<br />

In operation<br />

Alarm<br />

Getting ready<br />

Thermostat ON<br />

COOL<br />

HEAT<br />

FAN<br />

AC<br />

synchronization<br />

signal input circuit<br />

Remote<br />

controller<br />

communication<br />

circuit<br />

CPU<br />

H8/3039<br />

BUS<br />

communication<br />

circuit<br />

TA sensor<br />

TCI sensor<br />

TC2 sensor<br />

TCJ sensor<br />

Float input<br />

*Not applicable to concealed<br />

duct high static pressure type<br />

HA<br />

Sameas left<br />

*2<br />

R S<br />

U1 U2<br />

Sameas left<br />

*2<br />

R S<br />

U1 U2<br />

Up to 8 units can be<br />

connected. *1<br />

*1 Only up to 7 units if a<br />

network adaptor is<br />

installed with 2 main<br />

(sub) remote controllers<br />

connected.<br />

*2 The network adaptor can<br />

only be installed in one<br />

unit.<br />

*3 A weekly timer cannot<br />

be connected to a sub<br />

remote controller.<br />

Transformer<br />

Power source<br />

1Ø 220-240V, 50Hz<br />

1Ø 220V, 60Hz<br />

L N U1 U2<br />

Indoor/outdoor communication<br />

U1 U2<br />

Outdoor<br />

unit<br />

Power<br />

source<br />

Outdoor<br />

unit<br />

Power<br />

source<br />

Outdoor<br />

unit<br />

87

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!