16.04.2015 Views

MULTI TYPE

MULTI TYPE

MULTI TYPE

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Central<br />

control<br />

remote<br />

controller<br />

(optional)<br />

(In case of<br />

AI-NETWORK)<br />

X<br />

Y<br />

Main (sub) center remote controller (up to 2 units)<br />

Weekly timer<br />

Display<br />

LCD<br />

Display<br />

LED<br />

EEPROM<br />

CPU<br />

Function setting<br />

Key switch<br />

Display<br />

LCD<br />

LCD<br />

driver<br />

CPU<br />

Function setting<br />

Key switch<br />

Remote controller<br />

communication circuit<br />

DC5V<br />

Power<br />

supply<br />

circuit<br />

CN2 CN1<br />

*3<br />

Power<br />

supply<br />

circuit<br />

DC5V<br />

Rechargeable<br />

battery<br />

Indoor unit<br />

#1<br />

Network adaptor (optional)<br />

Network<br />

adaptor P.C.<br />

board<br />

(MCC-1401)<br />

AI-NET<br />

communication<br />

circuit<br />

DC5V<br />

Power supply circuit<br />

Transformer<br />

Remote controller<br />

communication<br />

circuit<br />

CPU<br />

H8/3687<br />

Switch setting<br />

Indoor control P.C. board (MCC-1402)<br />

DC20V<br />

DC12V<br />

DC5V<br />

A B #2 A B #3 A B<br />

Remote<br />

controller<br />

communication<br />

circuit<br />

CPU<br />

H8/3039<br />

EEPROM<br />

TA sensor<br />

TCI sensor<br />

TC2 sensor<br />

TCJ sensor<br />

Driver<br />

Sameas left<br />

*2<br />

Sameas left<br />

*2<br />

Up to 8 units can be<br />

connected. *1<br />

*1 Only up to 7 units if a<br />

network adaptor is<br />

installed with 2 main<br />

(sub) remote controllers<br />

connected.<br />

*2 The network adaptor can<br />

only be installed in one<br />

unit.<br />

PMV<br />

Louver<br />

motor<br />

*Not applicable to concealed duct<br />

standard type Slim Duct Type<br />

Drain<br />

pump<br />

Indoor<br />

fan<br />

motor<br />

DC 280V<br />

Power supply circuit<br />

CPU<br />

TMP88CH<br />

47FG<br />

(TMP88PH<br />

47FG)<br />

Fan motor<br />

control circuit<br />

External output<br />

In operation<br />

Alarm<br />

Getting ready<br />

Thermostat ON<br />

COOL<br />

HEAT<br />

FAN<br />

AC<br />

synchronization<br />

signal input circuit<br />

BUS<br />

communication<br />

circuit<br />

Float input<br />

HA<br />

R S<br />

U1 U2<br />

R S<br />

U1 U2<br />

*3 A weekly timer cannot<br />

be connected to a sub<br />

remote controller.<br />

Power source<br />

1Ø 220-240V, 50Hz<br />

1Ø 220V, 60Hz<br />

L N U1 U2<br />

Indoor/outdoor communication<br />

U1 U2<br />

Outdoor<br />

unit<br />

Power<br />

source<br />

Outdoor<br />

unit<br />

Power<br />

source<br />

Outdoor<br />

unit<br />

86