16.04.2015 Views

MULTI TYPE

MULTI TYPE

MULTI TYPE

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Central<br />

control<br />

remote<br />

controller<br />

(optional)<br />

X<br />

Y<br />

(In case of<br />

AI-NETWORK)<br />

Indoor unit<br />

#1<br />

Network adaptor (optional)<br />

Network<br />

adaptor P.C.<br />

board<br />

(MCC-1401)<br />

Remote controller<br />

communication<br />

circuit<br />

AI-NET<br />

communication<br />

circuit<br />

CPU<br />

H8/3687<br />

DC5V<br />

Power supply circuit<br />

Switch setting<br />

Transformer<br />

PMV<br />

Louver<br />

motor<br />

Drain<br />

pump<br />

* Not applicable to concealed duct high static pressure type<br />

Indoor<br />

fan<br />

motor<br />

Main (sub) center remote controller (up to 2 units)<br />

Weekly timer<br />

Display<br />

LCD<br />

Display<br />

LED<br />

EEPROM<br />

CPU<br />

Function setting<br />

Key switch<br />

Display<br />

LCD<br />

LCD<br />

driver<br />

CPU<br />

Function setting<br />

Key switch<br />

Remote controller<br />

communication circuit<br />

DC5V<br />

Power<br />

supply<br />

circuit<br />

CN2 CN1<br />

*3<br />

Power<br />

supply<br />

circuit<br />

DC5V<br />

Rechargeable<br />

battery<br />

A B #2 A B #3 A B<br />

Indoor control P.C. board (MCC-1403)<br />

DC20V<br />

DC12V<br />

Remote<br />

controller<br />

communication<br />

circuit<br />

EEPROM<br />

DC5V<br />

TA sensor<br />

Power supply circuit<br />

CPU<br />

H8/3039<br />

TCI sensor<br />

TC2 sensor<br />

TCJ sensor<br />

Float input<br />

*Not applicable to concealed<br />

duct high static pressure type<br />

HA<br />

Sameas left<br />

*2<br />

R S<br />

U1 U2<br />

Sameas left<br />

*2<br />

R S<br />

U1 U2<br />

Power source<br />

1Ø 220-240V, 50Hz<br />

1Ø 220V, 60Hz<br />

L N U1 U2<br />

Indoor/outdoor communication<br />

U1 U2<br />

Outdoor<br />

unit<br />

Power<br />

source<br />

Outdoor<br />

unit<br />

Power<br />

source<br />

Outdoor<br />

unit<br />

Up to 8 units can<br />

be connected. *1<br />

*1 Only up to 7<br />

units if a<br />

network<br />

adaptor is<br />

installed.<br />

*2 The network<br />

adaptor can<br />

only be<br />

installed in one<br />

unit.<br />

*3 A weekly timer<br />

cannot be<br />

connected to a<br />

sub remote<br />

controller.<br />

Driver<br />

* 1-way Type only<br />

Wireless remote controller kit<br />

Fan motor<br />

control circuit<br />

External<br />

output<br />

In operation<br />

Alarm<br />

Getting ready<br />

Thermostat ON<br />

COOL<br />

HEAT<br />

FAN<br />

AC<br />

synchronization<br />

signal input circuit<br />

BUS<br />

communication<br />

circuit<br />

Remote controller<br />

communication<br />

circuit<br />

Sensor<br />

section<br />

Display<br />

section<br />

Transformer<br />

93