(7) Install the service P.C. boards (A) and (B) in the outdoor unit controller.<br />

(Make sure that they are firmly secured to the card edge spacers (7).)<br />

(8) Securely connect the service P.C. boards to the chassis using the earthing screws (5), (6) removed in step 4.<br />

If either of the screws is loose, it will pose a risk of device failure by degrading noise control, so take care while<br />

engaging in the work.<br />

Nevertheless, do not use an electric or pneumatic screwdriver under any circumstances as it may lead to<br />

component damage.<br />

(9) Connect the wiring using the connectors and fastons removed in step 3.<br />

Make sure that the connectors and fastons are connected correctly and securely.<br />

(10)If any component on the P.C. board becomes crooked during replacement, straighten it without touching any<br />

other component.<br />

(11)Mount the terminal block sub-assembly (1) and firmly secure it using the screws (3).<br />

(12)Securely connect the red, white and black leads from the service P.C. board (A) to the power supply terminal<br />

block (4) using the screws (2).<br />

(13)Put the cover on, turn on the power, and check operation.<br />

Close-up view of screw-on terminals (8)<br />

Screw tightening torque (N•m)<br />

Screw diameter Torque (N•m)<br />

M6 2.5±0.1<br />

M4 1.2±0.1<br />

M3 0.5±0.1<br />

Close-up view of terminal<br />

block sub-assembly<br />