Check code Check code name<br />

Cause<br />

[F03] / [93]<br />

(AI-NET)<br />

Indoor TC1 sensor error TC1 sensor Open/Short<br />

Check code Check code name<br />

Cause<br />

[F01] / [0F]<br />

(AI-NET)<br />

Indoor TCJ sensor error TCJ sensor Open/Short<br />

Is TC1<br />

sensor connector<br />

(CN100: Brown) on indoor<br />

P.C. board normally<br />

connected?<br />

Yes<br />

No<br />

Correct connection of<br />

connector.<br />

Is TCJ<br />

sensor connector<br />

(CN102: Red) on indoor<br />

P.C. board normally<br />

connected?<br />

Yes<br />

No<br />

Correct connection of<br />

connector.<br />

Are characteristics<br />

of TC1 sensor resistance<br />

value normal?<br />

No<br />

Replace TC1 sensor. Are characteristics<br />

of TCJ sensor resistance<br />

No<br />

Replace TCJ sensor.<br />

value normal?<br />

Yes * See “Indoor unit temperature sensor characteristics” on “8-9. Sensor Characteristics”.<br />

Yes * See “Indoor unit temperature sensor characteristics” on “8-9. Sensor Characteristics”.<br />

Check indoor main P.C. board.<br />

Defect ➝ Replace<br />

Check indoor P.C. board.<br />

Defect ➝ Replace<br />

Check code Check code name<br />

Cause<br />

[F04] / [19]<br />

(AI-NET)<br />

TD1 sensor error TD1 sensor Open/Short<br />

This error code means detection of Open/Short of TD1 sensor. Check disconnection of circuit for connection of<br />

connector (TD1 sensor: CN502, White) and characteristics of sensor resistance value. (See “Outdoor unit temperature<br />

sensor characteristics” on “8-9. Sensor Characteristics”.)<br />

If sensor is normal, replace outdoor I/F P.C. board.<br />

Check code Check code name<br />

Cause<br />

[F02] / [0d]<br />

(AI-NET)<br />

Is TC2<br />

sensor connector<br />

(CN101: Black) on indoor<br />

P.C. board normally<br />

connected?<br />

Indoor TC2 sensor error TC2 sensor Open/Short<br />

No<br />

Correct connection of<br />

connector.<br />

Check code Check code name<br />

Cause<br />

[F05] / [A1]<br />

(AI-NET)<br />

TD2 sensor error TD2 sensor Open/Short<br />

This error code means detection of Open/Short of TD2 sensor. Check disconnection of circuit for connection of<br />

connector (TD2 sensor: CN503, Pink) and characteristics of sensor resistance value. (See “Outdoor unit temperature<br />

sensor characteristics” on “8-9. Sensor Characteristics”.)<br />

If sensor is normal, replace outdoor I/F P.C. board.<br />

Yes<br />

Are characteristics of<br />

TC2 sensor resistance<br />

value normal?<br />

Yes<br />

Check indoor P.C. board.<br />

Defect ➝ Replace<br />

No<br />

Replace TC2 sensor.<br />

* See “Indoor unit temperature sensor characteristics” on “8-9. Sensor Characteristics”.<br />

Check code Check code name<br />

Cause<br />

[F06] / [18]<br />

(AI-NET)<br />

TE1 sensor error TE1 sensor Open/Short<br />

This error code means detection of Open/Short of TE1 sensor. Check disconnection of circuit for connection of<br />

connector (TE1 sensor: CN505, Green) and characteristics of sensor resistance value. (See “Outdoor unit temperature<br />

sensor characteristics” on “8-9. Sensor Characteristics”.)<br />

If sensor is normal, replace outdoor I/F P.C. board.<br />