8-8. Leakage/Clogging of Refrigerating Cycle Circuit<br />

List of Check Codes Generated upon Occurrence of Leakage/Clogging in Outdoor Cycle<br />

or Oil Circuit Part<br />

(MMY-MAP0804, 1004, 1204)<br />

Clogging<br />

Outdoor PMV1, 2<br />

Leakage<br />

Part<br />

Check valve in discharge pipe<br />

convergent section<br />

Note: “XX” represents sub-code<br />

Site of fault<br />

(see next page)<br />

A<br />

B<br />

Unit generating<br />

check code<br />

Corresponding unit<br />

Corresponding unit<br />

Detected fault and check code<br />

Activation of high-pressure protection<br />

Activation of low-pressure protection<br />

Discharge temp. error (TD1)<br />

Discharge temp. error (TD2)<br />

High-pressure protection error<br />

High-pressure SW system error<br />

P20<br />

H06<br />

P03<br />

P17<br />

P20<br />

P04-XX<br />

Symptom<br />

Rise of pressure<br />

Fall of pressure<br />

Rise of discharge temp.<br />

(compressor 1)<br />

Rise of discharge temp.<br />

(compressor 2)<br />

Abnormal rise of pressure<br />

Check valve in discharge pipe C Corresponding unit High-pressure SW system error P04-XX Abnormal rise of pressure<br />

Check valve in oil-equalization circuit<br />

Capillary<br />

Strainer<br />

D<br />

Corresponding unit<br />

Oil level detection circuit error<br />

Oil level low detection and protection<br />

H16-XX<br />

H07<br />

SV3A valve E Other connected unit Oil level low detection and protection H07 Oil level low<br />

SV3B valve F Corresponding unit Oil level low detection and protection H07 Oil level low<br />

SV3C valve G Other connected unit Oil level low detection and protection H07 Oil level low<br />

SV3D valve<br />

SV3D valve circuit capillary<br />

Strainer<br />

H<br />

Corresponding unit Oil level low detection and protection H07 Oil level low<br />

SV3E valve<br />

I<br />

Corresponding unit<br />

Oil level detection circuit error<br />

Oil level low detection and protection<br />

H16-05<br />

H07<br />

Oil circuit error or oil level low<br />

Oil circuit error<br />

Oil level low<br />

Oil level low<br />

Oil return distributor J Corresponding unit Oil level low detection and protection H07 Oil level low<br />

SV3C bypass capillary K Corresponding unit Oil level detection circuit error H16-04 Oil circuit error<br />

Outdoor PMV1, 2<br />

Part<br />

Check valve in discharge pipe<br />

convergent section<br />

Check valve in discharge pipe<br />

Site of fault<br />

(see next page)<br />

A<br />

B<br />

C<br />

Unit generating<br />

check code<br />

Corresponding unit<br />

Other connected unit<br />

Corresponding unit<br />

Corresponding unit<br />

Detected fault and check code<br />

Outdoor liquid backflow error<br />

Oil level low detection and protection<br />

Discharge temp. error (TD1)<br />

Discharge temp. error (TD2)<br />

Oil level low detection and protection<br />

Compressor breakdown<br />

Compressor error (lockup)<br />

Oil level low detection and protection<br />

Compressor breakdown<br />

Compressor error (lockup)<br />

P13<br />

H07<br />

P03<br />

P17<br />

H07<br />

H01-XX<br />

H02-XX<br />

H07<br />

H01-XX<br />

H02-XX<br />

Symptom<br />

Refrigerant entrapment<br />

Rise of discharge temp.<br />

(compressor 1)<br />

Rise of discharge temp.<br />

(compressor 2)<br />

Refrigerant entrapment<br />

Refrigerant entrapment<br />

Check valve in oil-equalization circuit<br />

Corresponding unit Oil level low detection and protection H07 Excessive amount of oil<br />

D<br />

(Leaking side)<br />

Insufficient amount of oil<br />

(Normal side)<br />

SV3A valve E Corresponding unit Oil level low detection and protection H07 Oil level low<br />

SV3C valve G Corresponding unit Oil level low detection and protection H07 Oil level low<br />

232