Method 2<br />

If it is not possible to turn on the indoor unit or read the setting data from the P.C. board to be replaced via a wired<br />

remote controller or operate the remote controller due to the failure of its power supply circuit -<br />

Replacing EEPROM (IC503, IC10) (For the location of this component and the method to replace it, see the<br />

“ EEPROM Location Diagram” section.)<br />

• The EEPROM on the P.C. board to be replaced needs to be removed and mounted on the service P.C. board.<br />

Replacing P.C. board and turning on power: Procedure 2<br />

Reading EEPROM data: Procedure 1<br />

• If data cannot be read, go to Method 3.<br />

Replacing EEPROM (IC503, IC10) again (For the location of this component and the method to replace it, see the<br />

“ EEPROM Location Diagram” section.)<br />

• The old EEPROM, supplied with the P.C. board to be replaced and now mounted on the service P.C. board,<br />

needs to be replaced with the new EEPROM, supplied with the service P.C. board.<br />

Replacing P.C. board and turning on power: Procedure 2<br />

Writing EEPROM data in new EEPROM: Procedure 3<br />

Resetting power supply (applicable to all indoor units connected to remote controller in case of group operation)<br />

Method 3<br />

If it is not possible to read the setting data due to the failure of the EEPROM itself -<br />

Replacing P.C. board and turning on power: Procedure 2<br />

Writing EEPROM data on basis of information supplied by customer (e.g. high ceiling adjustment setting and<br />

optional connection setting): Procedure 3<br />

Resetting power supply (applicable to all indoor units connected to remote controller in case of group operation)<br />