4-2. Normal Operation (COOL Mode) - Low Outside Air<br />

Temperature (Roughly Below 20 °C)<br />

Header unit (MMY-MAP1604*)<br />

Follower unit (MMY-MAP1204*)<br />

FM<br />

FM<br />

TO<br />

TO<br />

PMV1<br />

PMV2<br />

PMV4<br />

TE2<br />

TE1<br />

TE1<br />

SV<br />

4-Way valve<br />

PMV1<br />

PMV2<br />

SV5<br />

4-Way valve<br />

Pressure sensor<br />

(high pressure)<br />

TS1<br />

TS1<br />

TL<br />

SV3D<br />

SV<br />

O.S.<br />

SV6 SV<br />

SV<br />

SV2<br />

Pressure sensor<br />

(low pressure)<br />

TL<br />

Pressure sensor<br />

(high pressure)<br />

SV3D<br />

SV<br />

O.S.<br />

Pressure sensor<br />

(low pressure)<br />

SV<br />

SV2<br />

Liquid tank<br />

SV41<br />

SV<br />

TD1<br />

SV3C<br />

HPS<br />

SV<br />

TK4<br />

Compressor<br />

1<br />

HPS<br />

Compressor<br />

2<br />

SV SV42<br />

TD2<br />

HPS<br />

Compressor<br />

3<br />

SV Accumulator<br />

SV43<br />

TD3<br />

Liquid tank<br />

SV SV41<br />

TD1<br />

HPS<br />

SV3C<br />

Compressor A3<br />

1<br />

SV<br />

SV SV42<br />

TD2<br />

HPS<br />

TK4 Compressor<br />

2<br />

Accumulator<br />

TK1<br />

TK2<br />

TK1<br />

TK2<br />

TK3<br />

SV3E<br />

SV<br />

TK5<br />

SV<br />

TK5<br />

SV3E<br />

SV SV3F<br />

SV3A<br />

SV<br />

SV3A<br />

SV<br />

SV<br />

SV3B<br />

SV<br />

SV3B<br />

Balance pipe<br />

Liquid pipe<br />

Gas pipe<br />

Gas pipe<br />

Liquid pipe<br />

PMV PMV<br />

PMV PMV<br />

TC2<br />

TC1<br />

TC2<br />

TC1<br />

TC2<br />

TC1<br />

TC2<br />

TC1<br />

TCJ<br />

TCJ<br />

TCJ<br />

TCJ<br />

Indoor unit<br />

High-pressure gas or condensate liquid refrigerant<br />

Evaporative gas refrigerant (low-pressure gas)<br />

Normal refrigerant line<br />

Note: With a 14 or 16 HP outdoor unit, the main heat exchanger and sub-heat<br />

exchanger may be switched over depending on the outside temperature and<br />

air conditioning loads.<br />

Note: The "header unit" is the outdoor unit to which the indoor-outdoor communication<br />

line is connected. All other outdoor units are called "follower units".<br />

(The diagram shows a 28 HP system (16 HP + 12 HP) as an example.)<br />