DCPL-K4A02<br />

Finishes : Repairs of surface defects, screening,<br />

floating, steel trowelling and brooming, special<br />

finishes.<br />

o) Curing : Methods and length of time.<br />

Copies of records and tests for the items noted above, as well as,<br />

records of corrective action taken shall be submitted to the Engineer for<br />

approval as may be desired.<br />

3.0 INSTALLATION<br />

All installation requirements shall be in accordance with IS:456 and as<br />

supplemented or modified herein or by other best possible standards<br />

where the specific requirements mentioned in this section of the<br />

specification do not cover all the aspects to the full satisfaction of the<br />

Engineer.<br />

3.1 Washing and Screening of Aggregates<br />

3.2 Admixture<br />

Washing and Screening of coarse aggregate shall be carried out to remove<br />

fines , dirts or other deleterious materials.<br />

Washing of fine aggregate shall not be allowed, Fine aggregates shall<br />

be screened only to remove dirt or other deleterious materials.<br />

However , all washing & screening of aggregates shall be carried out by<br />

approved means to ensure compliance with the aggregate specification.<br />

All concrete shall be designed for normal rate of setting and hardening at<br />

normal temperature. Variations in temperature and humidity under different<br />

climatic conditions will affect the rate of setting and hardening, which will,<br />

in turn, affect the workability and quality of the concrete.<br />

Admixtures may be permitted to be used in accordance with IS:456 to<br />

modify the rate of hardening, to improve workability or as an aid to<br />

control concrete quality. The Engineer reserves the right to require<br />

laboratory test or use test data, or other satisfactory reference before<br />

granting approval. The admixture shall be used strictly in accordance<br />

with the manufacturer's directions and/or as directed by the Engineer.<br />

3.3 Grades of Concrete<br />

(PCA.774.S034sca2) V.II-D2/S-III : 11