DCPL-K4A02<br />

g) Glazed beads, weather stripping, fixing devices etc. shall not be measured<br />

separately but shall be included in the supply rate of respective items.<br />

h) And cutting or grouting to concrete and masonry or welding and drilling to steel<br />

required for installation shall be included in the installation rate. No separate<br />

payment shall be made for cauking and jamming or frames or making good to<br />

concrete or masonry.<br />

i) Glass and glazing shall be measured and paid under relevant items.<br />

j) Door and window fixtures, locks, door closures etc. shall be measured in actual<br />

number use.<br />

7.0.0 I.S. CODES<br />

Following are some of the important I.S. Codes as relevant to this section :<br />

Steel doors, windows and ventilators - IS:1038<br />

Steel windows for industrial buildings - IS:1361<br />

Aluminium doors windows and ventilators - IS:1948<br />

Aluminium windows for industrial buildings - IS:1949<br />

Steel door frames - IS:4351<br />

Code of practice for fixing and glazing of<br />

metal (steel and aluminium) doors,<br />

windows, and ventilators - IS:1081<br />