DCPL-K4A02<br />

2.2.3 Aluminium Structural Glazing<br />

Providing and fixing of barriered semi unitised structural glazing system at<br />

all levels through designing and selection of mullion and transoms profiles<br />

anodised (15 to 20 micron) or powder coated (50 to 70 micron), selected for<br />

their fixing on the structure depending on the structural conditions, functional,<br />

statistical requirement and should withstand the wind load criteria as per IS-875<br />

(part - III) 1987. System should provide proper rebate areas for air pressure<br />

compensation / water drainage at required stages. Double insulated hard<br />

coated toughened glass consist of 6mm outer single safety glass, 12mm inter<br />

space and 6mm inner clear glass panel glued onto the glass glazing frame<br />

profile selected according to the vision / spandrel panel (Aluminium Composite<br />

Panels) requirement with DC 995 structural sealant. Proper supporting element<br />

should be provided for taking care of the respective infill load and reliving in<br />

case of the glass bonding failure. ( The profile sections shall be Hindalco -<br />

Alupuram unit, HYDRO product or equivalent). Floor to floor height would be<br />

4.2m approx and width of glazing supporting frame would be 1.0m approx.<br />

2.3.0 Shop Coat or Paint<br />

The shop paint for steel doors, windows etc. shall be best lead or zinc<br />

chromate primer paint from approved manufacturer. All surfaces shall be<br />

thoroughly cleaned of rust, grease, loose mill scales etc. and given one coat of<br />

shop paint. Portions like mullions, transoms etc. which will be inaccessible<br />

after assembly of units shall be given an extra coat of paint before assembly.<br />

All steel doors, windows, etc. shall be hot dip galvanised to give a coating<br />

weight of 1-1/2 - 2 oz. per sft. One coat zinc chromate primer coat shall then<br />

be applied as shop paint.<br />

Portions of aluminium frame which come in contact with masonry construction,<br />

shall, before shipment from workshop, be protected with a heavy coat of alkali<br />

paint. Aluminium coming in contact with other incompatible metals shall be<br />

coated with zinc chromate primer.<br />

2.4.0 Handling & Storage of Fabricated Material<br />

All metal doors, windows, etc. shall be packed and crated properly before<br />

despatch, to ensure that there will be no damage to the fabricated materials.<br />

Loading into wagons and trucks shall be done with all care to ensure safe<br />

arrival of materials at site in undamaged condition.<br />

When taking delivery of items supplied by Owner, the Contractor shall satisfy<br />

himself that the items supplied are upto the specified standard. Any defect<br />

detected shall promptly be brought to the notice of the Engineer.<br />

All metal doors, windows etc. shall be stored under cover in a way to prevent<br />

damage or distortion. Special care shall be taken to prevent staining of<br />

aluminium products by rust, mortar etc.<br />