OCPl-K9A01<br />

3.2.0 Reinforcement<br />

3.2.1<br />

Bending of Reinfortement<br />

t<br />

{<br />

3.2.2 Pladng<br />

All bars shall be carefuny and accurately bent by the Contractor in<br />

accordance with approved Drawings and ber bending schedules. Special<br />

care shall be taken to ensure correct lengths of laps. The bars shall not be<br />

bent or straightened in any manner that wiN Injure the bara or impair the bond<br />

between reinforcement & conae1e. Bends and hooks are to be provided as<br />

laid down in the IS:2502.<br />

All reinforcement shell be placed and maintained in the position shown in the<br />

drawings. Contractor shaR provide approved type of cover blocks to sUit the<br />

requirement of the Drawings. Where reinforcement Is to be provided on two<br />

faces of the shell, the Contractor shell provide adeqoate number of<br />

separators, with the approval of the Engineer. Any additional supporHo the<br />

re1nforcing cage. if required at the time of concreting, shall alSO: be provided,<br />

to the satisfaction of the Engineer. lapping of reinforcemenl as specified in<br />

the drawings or as directed by the Engineer, shall be provided. laps shall be<br />

staggered and too many laps shan be.avoided. Welded laps shall be<br />

provided only when directed or approved by the Engineer. '<br />

3.2.3 Fixing of Reinforcement<br />

18 SWG annealed steel wire shall be used as binding wire. 8ar crossing one<br />

another and contact laps shall be bound with this wire, twisted tight to make<br />

the skeleton or network rigid so that the reinforcement is not displaced during<br />

placing of concrete.<br />

3.10 Fonns<br />

( Construction by Slip-form Method<br />

." 1;.­<br />

Slip-fonm construction 'shaA !:le for constructioiI of the )oYind shield. Type of<br />

,~ Sfip-form proposed should be Indicated In the offer with sketches, drawings<br />

and. constnlCtioo ' statement ·aselCplained herein;;d'ter; !'lumber, type and '<br />

capacities of Jacks, the' control system and achievable rate of progress in<br />

t.:<br />

mmIhour should also be indicated. The chosen scheme shell be of a psst<br />

proven design. A certified perfonmance record of the scheme should be<br />

submitted with the offer to guarantee woikability of the scheme both from<br />

execution time and safety point of view. .<br />

t, ,<br />

t<br />

t:, '<br />

The Tenderer shQuld fumish a brief but commprehensive statement<br />

indicating the planning & programme and method of work to be followecUor<br />

the approval of Owner at the time of submitting Tender. This slstement shall<br />

include the following Hems:<br />

i) Type and description of SUp:form eq';lipment and its accessories.<br />

(PCA.CD-003.S60SCSA24,doc.dac) V.II-02lS-XXIV: 17<br />

L~ . ,., "<br />

325<br />

l'<br />

; .<br />

~,'..