Local Link Mode<br />

In Local Link mode, the compressors within an 8 fader section can linked<br />

together to form any size links in any combination, so that all the link<br />

members being compressed are treated as one and compressed<br />

identically.<br />

It is always the loudest signal within this link-group that causes the<br />

compressor to action once the threshold has been reached, regardless of<br />

which signal this actually is.<br />

Creating links will always link that path with the path to it's right.<br />

Links can be any size (from 2 to 8-wide) in any combination.<br />

It is possible to set up a single 8-wide link.<br />

It is not possible to link across different 8-fader sections of the console.<br />

A typical linking example would be channels 1 & 2 linked together, and<br />

channels 4 & 5 linked together to form two link groups.<br />

It would then be possible to include channel 3 to join these links together<br />

to form one complete link, but noting that channel 3 would also be<br />

included in the link group if selected.<br />

To isolate channel 3 it would be necessary to remove the compressor from<br />

the channel or the monitor path by using the DYN button (turned off) on<br />

the channel strip to isolate it.<br />

Global Link Mode<br />

In Global Link Mode all of the compressors across the entire width of the<br />

console will act as a single compressor across all of the signals fed into it.<br />

In Local or Global Link<br />

Mode, the Threshold, Ratio,<br />

etc values can all be<br />

different for paths that are<br />

linked, and all of these<br />

controls can be set<br />

independently of each other.<br />

It is the loudest signal in the<br />

group that will cause all of<br />

those linked dynamics to<br />

action at once.<br />

When linking the Dynamics<br />

using the F4 and F5 buttons,<br />

all of the these controls are<br />

linked and will hold the same<br />

values.<br />

It is always the loudest signal within this link-group that causes the<br />

compressor to action once the threshold has been reached, regardless of<br />

which signal this actually is.<br />

F1 – F5 buttons<br />

At the bottom of the DYN screen are function buttons, some of which<br />

match up with the F1 to F5 buttons just below the 4 encoders.<br />

Please see the section on EQ for a full explanation of these buttons and<br />

functions, on page 97.<br />

When linking Dynamics together in this way, all controls are linked apart<br />

from the Global/Local Link buttons.<br />

These will still operate independently of any links, and allow you to link<br />

controls, yet still allow the loudest signal within that group to cause the<br />

dynamics to action.<br />

NB:<br />

With regard to linking the Dynamics, it is irrelevant whether the<br />

Dynamics are operating on the channel input or DAW input<br />

section.<br />